  4. A smart recording power analyzer prototype Using LabVIEW and low-cost data acquisition (DAQ) in being a smart renewable monitoring system
Loading...
Thumbnail Image

A smart recording power analyzer prototype Using LabVIEW and low-cost data acquisition (DAQ) in being a smart renewable monitoring system

Author(s)
Chow, Chompoo Inwai
Mungkornassawakul, Jade
Date Issued
September 25, 2013
Type
Conference Paper
DOI
10.1109/GreenTech.2013.16
Abstract
Nowadays, to indicate the quality of Thailand's existing power system including the newly-installed distributed renewable energy sources, a number of pricy power quality analyzers are being used in most areas. This article proposes an alternative of such equipment called a smart recording power analyzer prototype (SRPA) using a combination of Lab VIEWTM algorithms and a low-cost data acquisition (DAQ) device. The newly-proposed set of equipment not only has the ability to achieve the same accuracy and functionalities of currently-used power analyzers, but also has the advanced features supporting Thailand's future-to-come smart grid system. The proposed SRPA is capable of simultaneous monitoring/recording both numerical data and waveforms in normal system operating conditions and when fault occurs e.g. voltage, current, frequency, real and reactive power, apparent power, energy consumption, power factor, harmonic distortion, voltage/frequency fluctuation, voltage unbalance, sag-swell, symmetrical components, flickers and many kind of faults detection. In this paper, the SRPA hardware configurations and Lab VIEWTM algorithms will be thoroughly elaborated. The accuracy verification process has been strictly done under various controllable conditions by comparing the results of the SRPA with the standard measuring units in both laboratory environment and two renewable energy power plants. Experimental results in the laboratory illustrate that the proposed SRPA is comparable in accuracy and far superior to several references in terms of functionalities and flexibilities. Experimental results from the two renewable power plants: (1) a 130kW-biogas pig farm power plant and (2) a 1MW solar power plant demonstrate that the proposed SRPA is highly efficient and reliable compared to the factory-installed measuring units. The average percent errors are less than 2%. The proposed SRPA also has the ability to be set up as a network which will be potentially beneficial for a future smart grid/micro grid online monitoring system. © 2013 IEEE.
Citation
IEEE Green Technologies Conference, 49-56, 2013
Subjects

Data acquisition (DAQ...

Flickers

LabVIEWTM

Power Quality

Renewable monitoring ...

Smart grid

Total Harmonics Disto...

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback