Repository logo
Communities & Collections
Research Outputs
Fundings & Projects
People
Statistics
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. KMITL
  3. Publication
  4. Augmented heat transfer in tubular heat exchanger fitted with V-baffled tapes
Loading...
Thumbnail Image

Augmented heat transfer in tubular heat exchanger fitted with V-baffled tapes

Author(s)
Promvonge, Pongjet
Skullong, Sompol
Date Issued
September 1, 2020
Type
Article
DOI
10.1016/j.ijthermalsci.2020.106429
Abstract
Effects of insertion of a straight tape mounted with double-sided V-baffles used as a longitudinal vortex generator (LVG) on turbulent convection heat transfer behaviors in a constant heat-fluxed tube in the Reynolds number (Re) range of 4120 to 25,800 are experimentally and numerically investigated. In the present experiment, the V-baffles at a fixed attack angle (α = 30°) were placed on the tape with two arrangements: V-apex pointing downstream and upstream (hereinafter called “V-down” and “V-up”). The V-down and up tapes with three baffle height ratios, (RB = b/D = 0.20, 0.15, 0.10) and pitch ratios, (RP = P/D = 1.5, 1.0, 0.5) were tested. Data of the current smooth or plain tube were also examined for comparison. The experimental results have shown that the employ of the V-down tape generally yields higher heat transfer, friction loss and thermal performance than that of the V-up one. A new derived thermal-performance enhancement factor (TEF) is proposed. The maximum TEF of the V-down tape is around 2.07 at RB = 0.15, RP = 1.0 and is, in average, about 1.4% higher than the V-up one having its peak of 2.04. A 3D numerical V-baffled-tube flow model was also simulated to examine the fluid flow and heat transfer patterns. The numerical validation was seen in close agreement with available experimental data. Numerical heat transfer contours and flow structures were also reported.
Citation
International Journal of Thermal Sciences, 155, 2020
Subjects

Forced convection

Thermal performance

Tubular heat exchange...

V-baffle

Vortex generator

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback