  4. In-line near infrared spectroscopy for the prediction of moisture content in the tapioca starch drying process
Loading...
Thumbnail Image

In-line near infrared spectroscopy for the prediction of moisture content in the tapioca starch drying process

Author(s)
Phetpan, Kittisak
Udompetaikul, Vasu
Sirisomboon, Panmanas
Date Issued
March 1, 2019
Type
Article
DOI
10.1016/j.powtec.2019.01.050
Abstract
Moisture content is an important parameter measured in tapioca starch production as this parameter has been shown to correlate strongly with the quality of the finished product. However, there is currently no in-line sensor which can be used to directly measure the moisture content of the product in real time. The objective of the present work was to study the use of an in-line measurement which can be introduced at the end of the drying process for tapioca starch moisture content evaluation. Either in-line NIR data or at-line NIR data was used to develop the necessary calibration models for evaluating the moisture content. Furthermore, calibration models were also developed by pooling the in-line and at-line data. Its performance was then verified using additional in-line data. The NIR model developed using 100% of the at-line data and 50% of the in-line data was validated using the unused 50% of the inline data. This model was shown to provide better performance in moisture content prediction with an SEP of 0.61% and a bias of 0.001%. In addition, the results showed that the at-line spectrum can also be used for the calibration model development to predict the moisture content of the samples scanned by an in-line spectrometer. However, the in-line spectrometer installation on a pneumatic conveying circular tube where tapioca starch and air mixed was found to be complicated due to significant vibration. This caused additional variation in the data with time. Therefore, it is concluded that the most suitable place for installing a spectrometer would be at a position involving a low pressure, or where the stream flow of a product is steadier in order to avoid the dynamic mixing of the product within the drying tube affecting the uncertainty of NIR scattering during the measurement.
Citation
Powder Technology, 345, 608-615, 2019
Subjects

Drying process

In-line near infrared...

Moisture content

Tapioca starch

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback