Foldable paper-based analytical device for membraneless gas-separation and determination of iodate based on fluorescence quenching of gold nanoclusters

Author(s)
Lert-itthiporn, Aurachat
Srikritsadawong, Pongpichet
Choengchan, Nathawut
Date Issued
January 1, 2021
Type
Article
DOI
10.1016/j.talanta.2020.121574
Abstract
A new design of a paper-based analytical device (PAD) for membraneless gas-separation with subsequent determination of iodate is presented. The rectangular PAD was invented as the folded pattern, where two circular reservoirs: the donor reservoir and the acceptor reservoir were situated in “a single paper” for convenient use. The hydrophobic barrier of each reservoir was easily fabricated by painting with a permanent marker. The PAD was demonstrated for the quantitative analysis of iodate, based on the fluorescence quenching of the bovine serum albumin-stabilized gold nanoclusters (BSA-AuNCs). The BSA-AuNCs were fast prepared by a microwave-assisted approach. The nanoclusters solution was applied into the acceptor reservoir, while the sample, iodide and sulfuric acid were sequentially aliquoted into the donor reservoir. After folding the PAD, the donor and the acceptor were mounted together via a two-sided mounting tape. The headspace between the two reservoirs allows membraneless gas-separation of free iodine from the donor to diffuse into the acceptor. Etching of gold core of the nanoclusters in the acceptor resulted in quenching of the red emission, was monitored by two methods, i.e. “fluorometric detection” (λex: 490 nm, λem: 630 nm) and “image capture” of the acceptor under the UV irradiation by a smart phone's camera. Two calibrations were plotted accordingly to their detections and good linearities (r2 ˃ 0.98) were observed from 0.005 to 0.1 mmol L−1 iodate. High accuracy (mean recovery: 95.1 (±4.6) %) and high precision (RSD < 3%) were obtained. The lower limits of detection were 0.005 mmol L−1 (with fluorometric detection) and 0.01 mmol L−1 (with image capture). The method was effectively applied for the measurement of iodate in iodized salts and fish sauces without prior sample pre-treatment.
Citation
Talanta, 221, 2021
Subjects

Foldable

Gold nanocluster

Iodate

Membraneless gas-sepa...

Paper-based analytica...

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback