Repository logo
Communities & Collections
Research Outputs
Fundings & Projects
People
Statistics
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. KMITL
  3. Publication
  4. Bangkok school indoor air quality: monitoring and intervention by positive pressure fresh air system
Loading...
Thumbnail Image

Bangkok school indoor air quality: monitoring and intervention by positive pressure fresh air system

Author(s)
Ongwandee, Maneerat
Khianthongkul, Kiraphat
Panyametheekul, Sirima
Yongprapat, Kamomchai
Srinaka, Kessara
Morris, John
Date Issued
April 1, 2024
Type
Article
DOI
10.1007/s11356-024-32843-8
Abstract
A PM2.5 crisis in Thailand has caused the Thai government and public to be increasingly concerned about children’s exposure to PM2.5 during time in school. This study is a part of a project to create a modeled effective school indoor air quality management for the Bangkok Metropolitan Administration (BMA). We measured air quality and environment in 10 Bangkok school rooms, including CO2, CO, O3, PM2.5, PM10, TVOCPID, formaldehyde, airborne bacteria and fungi, and gaseous organic contaminants. The indoor-to-outdoor concentration ratios indicated that either outdoor sources or indoor + outdoor sources were the predominant contributors to PM in naturally ventilated classrooms. Meanwhile, PM levels in air-conditioned classrooms strongly depended on class activities. CO2 measurements showed that the air-conditioned classrooms had a low 0.4 per hour air change rate and total fungal counts also reached 800 CFU m−3. Analysis of gaseous organic compounds showed that the two most abundant were aliphatic and aromatic hydrocarbons, accounting for 60% by mass concentration. Interestingly, 2‐ethyl‐1‐hexanol, a mucous membrane irritant, was detected in all study rooms. In one naturally ventilated classroom, we implemented a positive pressure fresh air system to mitigate in-class PM levels; it kept PM levels below 20 μg m−3 throughout the class day. Students reported a 20–37% increase in satisfaction with the perceived indoor environmental quality and reported reduced rates in all symptoms of the sick building syndrome after implementing the positive pressure system.
Citation
Environmental Science and Pollution Research, 31(17), 25454-25467, 2024
Subjects

Indoor environmental ...

PM2.5

Positive pressure fre...

School indoor air qua...

Ventilation

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback