Repository logo
Communities & Collections
Research Outputs
Fundings & Projects
People
Statistics
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. KMITL
  3. Publication
  4. An improved Current Voltage Transferring Device for high current high frequency measurement
Loading...
Thumbnail Image

An improved Current Voltage Transferring Device for high current high frequency measurement

Author(s)
Pattanadech, Norasage
Kando, Masaaki
Date Issued
October 1, 2018
Type
Article
DOI
10.1016/j.epsr.2017.06.015
Abstract
This paper represents the characteristics of the improved Current Voltage Transferring Device (CVTD) for high current measurement including lightning impulse currents. The improved CVTD has been developed from the prototype CVTD to provide exceptional characteristics for high current with high frequency measurement. The improved CVTD in h-shaped configuration is made of copper and aluminium. The relationship between input current and output voltages of the new CVTD was investigated with short and long duration lightning impulse currents to establish the empirical formulas. The typical impulse current generator was used to generate 8/20 μs lightning impulse current with the amplitude of 940 A while the impulse generator with crowbar elements was utilized to generate 10/350 μs lightning impulse current with magnitude of 30.2 kA for the experiment. The lightning impulse current measurement characteristics of the CVTD and Rogowski coil were examined. From the experiments, the new improved CVTD shows the superior characteristics to measure the impulse currents with very fast rise time. Besides, nanosecond pulses superimposed on the lightning impulse currents were detected by only the improved CVTD. According to the experiments, there is no doubt that the new improved CVTD is a superior one for high current with high frequency measurement especially lightning impulse currents.
Citation
Electric Power Systems Research, 163, 767-773, 2018
Subjects

Current transformer

Current Voltage Trans...

Lightning current

Lightning current gen...

Printed circuit board...

Rogowski coil

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback