Repository logo
Communities & Collections
Research Outputs
Fundings & Projects
People
Statistics
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. KMITL
  3. Publication
  4. Partial Discharge Detection beyond the Frequency Ranges of IEC 60270
Loading...
Thumbnail Image

Partial Discharge Detection beyond the Frequency Ranges of IEC 60270

Author(s)
Rajakrom, Asawin
Cheechang, Chayapitch
Laochu, Prechapol
Nimsanong, Phethai
Yutthagowiht, Peerawut
Date Issued
January 1, 2024
Type
Conference Paper
DOI
10.1109/ICD59037.2024.10613175
Abstract
Due to the high background noise encountered during on-site partial discharge (PD) detection of power cables, calibrating PD detection systems at low PD levels becomes challenging, resulting in low sensitivity of PD detection systems. Achieving a 1-nC PD charge within the frequency range recommended by IEC 60270, which is lower than 1 MHz, is often difficult in practice. This paper presents an analysis of PD pulse currents in the frequency domain and proposes an alternative approach for PD detection during on-site testing of power cables. In the proposed method, the center frequency for PD detection is shifted to frequencies exceeding one megahertz, which lies outside the recommended frequency ranges of IEC 60270. Typically, the center frequency falls within the range of 1.5 MHz to 2.5 MHz, with a frequency bandwidth of several hundred kilohertz. By utilizing such frequency ranges, the signal-to-noise ratio of the PD pulse current significantly increases compared to the standard approach. Despite falling outside the standard-recommended frequency ranges, this adjustment allows for calibration using a 50-pC PD charge.
Citation
Proceedings of the 2024 IEEE 5th International Conference on Dielectrics Icd 2024, 2024
Subjects

high-voltage test

noise effect

on-site test

partial discharge

power cables

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback