  4. A Photoplethysmographic Signal Isolated from an Additive Motion Artifact by Frequency Translation
Loading...
Thumbnail Image

A Photoplethysmographic Signal Isolated from an Additive Motion Artifact by Frequency Translation

Author(s)
Sinchai, Sakkarin
Kainan, Pattana
Wardkein, Paramote
Koseeyaporn, Jeerasuda
Date Issued
August 1, 2018
Type
Article
DOI
10.1109/TBCAS.2018.2829708
Abstract
Acquiring a precise percentage of oxygen saturation (SpO2) from a finger-probe pulse oximeter is dependent on both artifact-free red and infrared photoplethysmoghaphic (PPG) signals. Nonetheless, in real-life situations, these PPG signals are corrupted by a motion artifact (MA) signal that is generated from either finger or hand movement. To resolve this MA interference, the cause of the adulteration of PPG signals by the MA signal is examined. The MA signal is found to behave like an additive noise. Additionally, the frequency responses of the MA and PPG signals show that these signals are in the same frequency band. Hence, instead of direct current, a sinusoidal wave alternating current is proposed to drive an LED source in order to shift the PPG frequency band away from the MA frequency band. Experimentally, a commercial finger-probe pulse oximeter is employed. To determine the performance of the presented scheme, the resulting PPG signals are compared with those from employing the old-fashioned LED-driving method. In addition, the accuracy is verified by computing the SpO2 value. The results reveal that the proposed approach successfully retains the fundamental morphologies of the PPG structures when motion occurs. Moreover, the calculated SpO2 values from the proposed technique provide an average error of approximately 1.4%, whereas the conventional method yields a mean error approximately 4.2%.
Citation
IEEE Transactions on Biomedical Circuits and Systems, 12(4), 904-917, 2018
Subjects

Amplitude modulation

Motion artifact (MA)

optical biosensor

photoplethysmography ...

pulse oximeter

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback