Repository logo
Communities & Collections
Research Outputs
Fundings & Projects
People
Statistics
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. KMITL
  3. Publication
  4. Wide area robust centralized power oscillation dampers design for DFIG-based wind turbines
Loading...
Thumbnail Image

Wide area robust centralized power oscillation dampers design for DFIG-based wind turbines

Author(s)
Surinkaew, Tossaporn
Ngamroo, Issarachai
Date Issued
February 10, 2014
Type
Conference Paper
DOI
10.1109/PSCC.2014.7038435
Abstract
Inter-area oscillations are associated with machines in one part of the system oscillating against machines in other parts of the system. They are caused by two or more groups of machines that are interconnected by weak ties. To damp out the inter-area oscillations, this paper proposes the new application of wide area stability control for robust centralized power oscillation dampers (PODs) design of doubly-fed induction generator (DFIG) wind turbines. The POD with 2nd-order lead/lag compensator structure for each DFIG wind turbine is located at the control center. To stabilize the target inter-area mode effectively, the geometric measures of controllability and observability are used to choose the suitable DFIG wind turbine for stabilizing the target oscillation mode, the proper input signal of POD, and the location of phasor measurement units (PMUs). The input signal of each POD is obtained from PMU while the output signal is transmitted to the rotor side converter voltage controller of DFIG. As a result, the reactive power output of DFIG can be modulated to damp out inter-area oscillations. In the POD parameters optimization, the wide range of power output levels of DFIGs and synchronous generators, time delays due to wide area communication, and unstructured system uncertainties model are taken into account so that the damping of inter-area modes and the system robust stability margin against uncertainties can be guaranteed. Solving the problem by the firefly algorithm automatically, the optimal parameters of PODs can be achieved. The stabilizing performance and robustness of the proposed robust centralized POD are evaluated in the IEEE New England 39 bus system by eigenvalue analyses and nonlinear simulation in scenarios with severe short circuits, N-1 outage contingencies, heavy power flows, and line tripping.
Citation
Proceedings 2014 Power Systems Computation Conference Pscc 2014, 2014
Subjects

doubly-fed induction ...

inter-area oscillatio...

robust control

wide area stability c...

wind turbine

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback