Repository logo
Communities & Collections
Research Outputs
Fundings & Projects
People
Statistics
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. KMITL
  3. Publication
  4. Greener, rapid and reliable UHPLC using 1-alkyl-3-methylimidazolium-based ionic liquids as the mobile phase additives for simultaneous determination of steroids and antihistamines residues in herbal medicines
Loading...
Thumbnail Image

Greener, rapid and reliable UHPLC using 1-alkyl-3-methylimidazolium-based ionic liquids as the mobile phase additives for simultaneous determination of steroids and antihistamines residues in herbal medicines

Author(s)
Nusai, Krittaya
Doungdee, Prayong
Date Issued
January 1, 2018
Type
Article
Abstract
The objective of this research was to develop and validate UHPLC using 1-alkyl-3-methylimidazolium-based ionic liquids as the mobile phase additives for simultaneous determination of steroids and antihistamines residues in herbal medicines. Steroids(prednisolone, dexamethasone) and antihistamines(cetirizine, loratadine) were examined. Various factors such as acetonitrile quantity, ionic liquid concentration, alkyl chain length on imidazolium cation of ionic liquid and UHPLC elution technique were investigated to obtain the optimum condition and to understand the separation mechanism. The separation mechanism involves hydrophobic and electrostatically repulsive interactions. The optimum condition was the mobile phase containing a mixture of 30:70, v/v acetonitrile and 1 mM aqueous ammonium acetate solution at pH 3.0 consisted of 2 mM [BMIm][BF4] as the additive with the gradient flow rate of 0.3-0.7 mLmin-1, an analytical column was C18(Kinetex; end capping; 2.6 μm; 2.1 mm i.d. × 100 mm), column temperature was 40 °C and UV detection was performed at 230 nm. The proposed method spent 2.07 mL of acetonitrile per 1 analysis which is the lowest quantity of acetonitrile in the mobile phase when compared with the previous methods. The analysis time of 15 minutes was obtained. The regression coefficient (R2) more than 0.9995 within 1.0-40.0 μg/mL were obtained for all four analytes. The obtained LOQ values were 1.80, 2.67, 1.90 and 3.23 μg/mL for prednisolone, dexamethasone, cetirizine and loratadine, respectively. The obtained LOD values were 0.58, 0.73, 0.57 and 1.04 μg/mL for prednisolone, dexamethasone, cetirizine and loratadine, respectively. No interferences were presented at their retention times. The accuracy expressed in term of recoveries, the obtained average %recoveries and % relative standard deviation (%RSD) of all steroids and antihistamines in three real herbal medicines were in the range of 84.5-110.7 %(n = 9) and within 5.5%, respectively. Precision of method in term of the % RSD of intra-and inter-day variations was within 5.3%. The proposed method could determine 107.40 ± 2.54 μg/mL of prednisolone in Andrographis paniculata, 9.24 ± 0.79 μg/mL of dexamethasone and 14.11 ± 1.24 μg/mL of cetirizine in Curcuma longa linn, 0.48 ± 0.07 μg/mL of prednisolone and 0.30 ± 0.03 μg/mL of dexamethasone in Relieves schmerzen herbal.
Citation
Chiang Mai Journal of Science, 45(1), 380-403, 2018
Subjects

Antihistamines

Ionic liquids

Mobile phase additive...

Steroids

UHPLC

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback