  4. Partial Discharge Phenomena in Power Capacitor Unit Insulation Under Harmonic Resonance Effects
Loading...
Thumbnail Image

Partial Discharge Phenomena in Power Capacitor Unit Insulation Under Harmonic Resonance Effects

Author(s)
Boonseng, Chongrag
Boonseng, Rapeepornpat
Boonsaner, Nutthaphan
Kinnares, Vijit
Apiratikul, Promsak
Kularbphettong, Kunyanuth
Date Issued
January 1, 2020
Type
Conference Paper
DOI
10.1007/978-3-030-31676-1_51
Abstract
The capacitor in the electrical system for power factor correction is always damaged when under voltage and current waveforms are distorted. There was a test found that the electrical insulation was damaged and destroyed. In order to learn this damage mechanism it requires a non-destructive inspection method. The partial discharge (PD) testing is a method that can detect deterioration and a defect in the electrical insulating material that is not visible. The purpose of this paper is to investigate the impact of harmonic resonance on power capacitor unit insulation. High voltage capacitor units consist of parallel and series connected elements. The rating of element of capacitor units applied in the power system is 6.67 kVAR/Phase, 400 V. Series resonance can lead to high voltage distortion levels at a low voltage side of transformer resulting in high harmonic current in the element of capacitors. The inspection and element of capacitor unit test are used to obtain power system resonance, a standard operating procedure, testing and measurement between phase to ground using the partial discharge model MPD 600 OMICRON, dielectric losses and capacitance model CPC 100 OMICRON. Finally, the scanning electron microscope (SEM) is used. The comparison of results between new element of capacitor and element under harmonic resonance are performed. The results convey that breakdown in insulating of capacitors under harmonic resonance can be used for considering capacitor voltage rating. The failure of insulation an increase in obtained and emphasized by photograph from SEM.
Citation
Lecture Notes in Electrical Engineering, 598 LNEE, 534-548, 2020
Subjects

Breakdown of insulati...

Harmonic resonance

Partial discharge

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback