Publication: Analysis and investigation on the behavior and performance of single phase grid connected induction generators system
Loading...
Date
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
This paper presents an inrush current reduction method for a 1/2 HP (0.4 kW), 220 V, 4.8 A, 4 poles single phase split-phase type induction generator when connected to a grid using single-phase voltage control with power electronic equipment. A study and analysis of relationship between voltage, current and real power by laboratory tests under direct on line and soft connection conditions are given. Simulation and experimental results are in good agreement. According to testing results, it is found that the proposed voltage control is able to reduce 75-80 % of the inrush current when starting the connection. Research results will be guidelines in applications of effective single-phase induction generators for wind energy.
Description
Keywords
Inrush current, Phase control, Single-phase induction generator, Voltage controller
Citation
2017 20th International Conference on Electrical Machines and Systems Icems 2017, 2017