Analysis of exergy and heat transfer in a tube fitted with flapped V-baffles

Author(s)
Jayranaiwachira, Nuthvipa
Promvonge, Pongjet
Tongyote, Paritkavin
Skullong, Sompol
Nakhchi, Mahdi Erfanian
Date Issued
July 1, 2024
Type
Article
DOI
10.1016/j.csite.2024.104483
Abstract
Vortex generator is a device that shows promise in generating streamwise vortices that can be utilized for boosting the rate of heat transmission inside a cooling/heating system with a relatively smaller penalty in terms of friction loss. The primary goal of the current research is to maximize the comparative Nusselt number ratio (Nu/Nu0) to be as large as possible to lower the size of the system while keeping thermal performance as high as feasible to save more energy. Thus, in the current study, the impacts of inserting the flapped V-baffle vortex generator (FBVG) on the thermal effectiveness improvement of a round tube were experimentally investigated. At a fixed attack angle (α = 60°) and baffle blockage ratio (BR = b/D = 0.3), the geometrical behaviors of FBVGs placed periodically along two edges of a straight tape were six different flap angles (θ = 0°, 25°, 35°, 45°, 65° and 90°) and three ratios of baffle pitches (P/D = PR = 2.0, 1.5, and 1.0). The current V-baffles, which were positioned on both tape edges, were designed to reduce friction loss caused by interrupting the central core flow when placed on both tape sides. The measurement results focused on the friction loss and thermal behaviors, including exergy and entropy analyses for Reynolds number from 4750 to 29,270. In the findings, the Nusselt number and friction factor of FBVG at θ = 0° and PR = 1 are, respectively, up to 5.6 and 35.24 times larger than those of the smooth tube. The entropy generation (S˙gen′) seems to decline as θ and PR increase, with the smallest S˙gen′ found at θ = 0° and PR = 1 for lower Re. The FBVG has the greatest exergy efficiency (ηEx) at θ = 0° and PR = 1. To find the true benefits of FBVG, its thermal performance is estimated and seen to reach a maximum at about 2.44 with NuR = 4.65 at θ = 45° and PR = 1. The optimal scenario at θ = 25° and PR = 1 was preferred, however, since it yielded the largest NuR = 5.42 at TEF = 2.39.
Citation
Case Studies in Thermal Engineering, 59, 2024
Subjects

Entropy generation

Exergy efficiency

Heat exchanger

Thermal performance

Vortex generator

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback