Repository logo
Communities & Collections
Research Outputs
Fundings & Projects
People
Statistics
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. KMITL
  3. Publication
  4. Poly(dimethylsiloxane) microlens array integrated with microfluidic channel for fluorescence spectroscopy detection
Loading...
Thumbnail Image

Poly(dimethylsiloxane) microlens array integrated with microfluidic channel for fluorescence spectroscopy detection

Author(s)
Rujihan, Suparat
Damrongsak, Badin
Kittidachachan, Pattareeya
Date Issued
September 18, 2013
Type
Conference Paper
DOI
10.1117/12.2022004
Abstract
Fluorescence spectroscopy detection has been commonly used in chemical and biochemical applications as it provides a good reliability and high sensitivity. Commercially available fluorescence spectroscopy system is typically bulky and expensive, hence making it inconvenience for on-site measurement which requires portable systems. However, the drawback of small devices is that it has a low detection volume, resulting in low fluorescence signal. In this paper, we report a microfluidic channel implemented with a microlens array for enhancing the performance of fluorescence spectroscopy detection. The microlens array was used to focus an excitation light onto the microchannel, thus expecting the increase in fluorescence detection signal. Both microchannels and microlens arrays were individually fabricated from poly-dimethylsiloxane (PDMS) using low-cost printed-circuit-board master molds. The fabrication and characterization of PDMS-based microlens arrays are discussed. In short, the microlens in plano-convex shape was designed with diameters of 700, 800 and 900 microns. The fabricated microlens arrays were characterized for radius of curvatures, SAGs and focal lengths. The plano-convex microlens array was then integrated into a microfluidic system in order to investigate the overall performance of fluorescence spectroscopy detection. Experiments were conducted with two fluorescence dyes, i.e. Rhodamine 6G and Coumarin 153. The preliminary results revealed that the PDMS microlens array implemented on the designed system shows potential for improving excitation and emission light intensity and, as a consequence, signal to background ratio of the fluorescence spectroscopy detection. © 2013 SPIE.
Citation
Proceedings of SPIE the International Society for Optical Engineering, 8883, 2013
Subjects

Chemical sensor

Fluorescence detectio...

Lab-on-a-chip

PDMS microlens

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback