Repository logo
Communities & Collections
Research Outputs
Fundings & Projects
People
Statistics
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. KMITL
  3. Publication
  4. A comparative study of non-enzymatic glucose detection in artificial human urine and human urine specimens by using mesoporous bimetallic cobalt-iron supported N-doped graphene biosensor based on differential pulse voltammetry
Loading...
Thumbnail Image

A comparative study of non-enzymatic glucose detection in artificial human urine and human urine specimens by using mesoporous bimetallic cobalt-iron supported N-doped graphene biosensor based on differential pulse voltammetry

Author(s)
Janyasupab, Metini
Liu, Chen Wei
Chanlek, Narong
Chio-Srichan, Sirinart
Promptmas, Chamras
Surareungchai, Werasak
Date Issued
May 1, 2019
Type
Article
DOI
10.1016/j.snb.2019.02.018
Abstract
Development of non-invasive glucose measurement allows future advancement of smart sensing platform for diagnostic technology. Especially for endocrine disorders, advanced kidney diseases, and diabetes, monitoring excessive glucose level in urine can provide invaluable information for clinical prognosis and preventive healthcare. Herein, we present a comparative electrochemical study of cobalt/iron (CoFe) catalyst on nitrogen-doped graphene (NG) for non-enzymatic glucose detection, carried out in physiological pH urine including (i) modified artificial urine medium (mAUM), (ii) commercial standard urine (Surine), and (iii) human urine specimens. With no requirement of strong alkaline addition, catalytic properties of CoFe-NG were assessed by using cyclic voltammetry (CV) and differential pulse voltammetry (DPV) on a glassy carbon rotating disk electrode. Upon successive glucose additions from 0 to 3 mM, DPV results revealed two anodic peaks at +0.18 V and +0.42 V versus Ag/AgCl, corresponding to Co3+ and Co4+ as a result of glucose binding in urine. By evaluating at +0.18 V, the sensitivities of CoFe-NG were estimated to be 16.77 (R2 = 0.987), 45.36 (R2 = 0.988), and 20.26 (R2 = 0.991) μA mM−1 cm−2 with the limit of detection of 0.25, 0.07, and 0.19 mM in mAUM, Surine, and human urine specimen with low serum creatinine, respectively. Furthermore, the effects of CoFe on graphene (G) and carbon Vulcan XC-72 (C) were also studied in comparison of NG on the bimetal. Interestingly, CoFe-C showed a good electrochemical trend in glucose detection in urine. However, negligible catalytic activity was presented in CoFe-G. Thus, electrochemical responses of CoFe-C were also further studied in the comparison of CoFe-NG in each type of urine. Overall, CoFe-NG outperformed CoFe-C in all types of urine and exhibited an excellent anti-interference property toward uric acid, thereby suggesting great potential for the next generation of glucose sensing platform in urine.
Citation
Sensors and Actuators B Chemical, 286, 550-563, 2019
Subjects

Bimetallic catalyst

Glucose in urine

Non-enzymatic detecti...

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback