Repository logo
Communities & Collections
Research Outputs
Fundings & Projects
People
Statistics
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. KMITL
  3. Publication
  4. A Contactless Edge-AI Prototype for Simulated Apnea-like Respiratory Suppression and Motion Artifact Detection Using 60 GHz FMCW Radar
Loading...
Thumbnail Image

A Contactless Edge-AI Prototype for Simulated Apnea-like Respiratory Suppression and Motion Artifact Detection Using 60 GHz FMCW Radar

Author(s)
Pairoch, Sathit
Phasukkit, Pattarapong
Houngkamhang, Nongluck
Date Issued
July 1, 2026
Type
Article
DOI
10.3390/technologies14070388
Abstract
Sleep-related respiratory disturbances are difficult to monitor continuously outside specialized laboratories because conventional polysomnography is resource-intensive and intrusive. This study presents a contactless edge-AI engineering prototype for detecting controlled voluntary respiratory-motion suppression and motion artifacts using a 60 GHz frequency-modulated continuous-wave radar. The system integrates a 60 GHz radar front end, lightweight local preprocessing, an INT8 one-dimensional convolutional neural network deployed on the Analog Devices MAX78000 CNN accelerator (Analog Devices Thailand, Chon Buri, Thailand), and an event-driven Raspberry Pi Zero 2W gateway for alert transmission. Evaluation was performed using a controlled healthy-volunteer dataset consisting of normal breathing, voluntary breath-holding-induced respiratory suppression, and deliberate motion artifact. The final valid test set contained 270 technically valid 30 s windows balanced across the three classes. The INT8 model achieved an overall accuracy of 92.6% (95% confidence interval: 88.8–95.2%), with a macro-averaged precision, recall, and F1-score of 92.6%, 92.6%, and 92.5%, respectively. Active CNN inference on the MAX78000 consumed 0.152 ± 0.011 mJ and was completed in 5.20 ± 0.11 ms, corresponding to approximately 280-fold lower active inference energy than Python 3.14.6/TensorFlow Lite 2.21.0-based execution on the Raspberry Pi Zero 2W. These results demonstrate the feasibility of privacy-aware, low-power respiratory-pattern classification at the edge. However, the study should be interpreted strictly as an engineering proof-of-concept based on controlled voluntary breathing and movement tasks in healthy volunteers. It is not a clinically validated apnea or obstructive sleep apnea detection system and did not include polysomnography, oxygen saturation measurement, airflow sensing, sleep staging, or diagnosed patient cohorts.
Citation
Technologies, 14(7), 2026
Subjects

1D-CNN

60 GHz FMCW radar

contactless respirato...

edge-AI

low-power inference

MAX78000

motion artifact

respiratory motion su...

TinyML

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback