Enhanced thermal performance in tubular heat exchanger contained with V-shaped baffles

Author(s)
Promvonge, Pongjet
Skullong, Sompol
Date Issued
February 25, 2021
Type
Article
DOI
10.1016/j.applthermaleng.2020.116307
Abstract
The vortex-flow device is a promising streamwise vortex generator employed to produce the counter-rotating vortices along a heated tube to augment the heat transfer rate with comparatively smaller friction loss penalty. Thus, the influences of V-shaped baffle vortex generator (hereafter called “V-baffle”) insert in a heated tube on thermal-performance enhancement were experimentally examined in the current work. The geometric characteristics of the V-baffles mounted repeatedly on the edges of a flat plate/tape were three ratios of relative baffle blockages, (b/D = BR = 0.1, 0.15 and 0.2), and four ratios of baffle pitches, (P/D = PR = 0.5, 1.0, 1.5 and 2.0) at a fixed angle of attack (α = 30°). The present V-baffle placed on the tape edge was aimed to lessen the pressure loss from disturbing the central core flow for the case of placing it on the double sides of a tape as found in the literature. The experiment was conducted by letting air flow through the test tube with Reynolds number (Re) in the range of 4192 to 25,750. The current study indicated that the friction factor and heat transfer using the V-baffle inserts increase considerably with rising BR but reducing PR. The V-baffle with BR = 0.2, PR = 0.5 provides the highest friction factor and rate of heat transfer at about 18.25 and 4.46 times above the plain tube, respectively. A new modified thermal enhancement factor (TEF) is offered and found that its peak for each case appearing at the lowest Re, is in a range of 2.14–2.34 where the optimum TEF of 2.34 is visible at PR = 1.0, BR = 0.15. Furthermore, correlations of Nusselt number and friction factor for the present V-baffles are determined. TEF of the current device is found to be superior to that of other enhanced devices in comparison.
Citation
Applied Thermal Engineering, 185, 2021
Subjects

Friction loss

Heat exchanger

Thermal performance

V-shaped baffle

Vortex generator

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback