Repository logo
Communities & Collections
Research Outputs
Fundings & Projects
People
Statistics
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. KMITL
  3. Publication
  4. Dielectric response analysis for cable joint problems in medium voltage underground cable system
Loading...
Thumbnail Image

Dielectric response analysis for cable joint problems in medium voltage underground cable system

Author(s)
Klienhom, Sitthisak
Boonsaner, Nutthaphan
Nimsanong, Phethai
Chancharoensook, Phop
Kunakorn, Anantawat
Pattanadech, Norasage
Date Issued
January 1, 2020
Type
Conference Paper
DOI
10.1007/978-3-030-31680-8_102
Abstract
This paper represents the investigation of dielectric response analysis of a cable system composed of a medium voltage XLPE underground cable, a heat-shrink cable joint and a heat-shrink cable termination. A 12/20(24) kV single core XLPE underground cable with the nominal cross-section area of 240 mm2, three pieces of 22 kV cable joints, and eight pieces of 22 kV cable termination were prepared for the experiment. Then, polarization and depolarization current (PDCs) measurement were performed. The experiments were divided into two parts. The first part was composed series of three tests, A — C, and the second part consisted series of two tests, D — E, as follows: Test A examined dielectric response of a 6 m healthy XLPE underground cable, Test B examined dielectric response of a 6 m healthy XLPE underground cable with two healthy cable terminations, Test C examined dielectric response of a two of 3 m healthy XLPE underground cable with healthy cable terminations connected by a healthy cable joint, Test D used the test object similarly as case C but the cable joint was contaminated with copper particles, and Test E used the test object similarly as case C but the cable joint was contaminated with tiny pieces of water blocking. From the experiment, the PDCs and the derived dielectric parameters such as geometrical capacitance, insulation resistance, polarization index, depolarization index, charge difference curve and charge ratio curve were analyzed. The PDCs and the derived parameters were found different for each case of study as details in this paper. Besides, the charge ratio proposed by authors is a valuable parameter for the diagnosis of insulation system of high voltage equipment.
Citation
Lecture Notes in Electrical Engineering, 599 LNEE, 1056-1064, 2020
Subjects

Cable joint

Charge ratio analysis...

Dielectric response a...

Polarization and depo...

Underground cable

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback