Repository logo
Communities & Collections
Research Outputs
Fundings & Projects
People
Statistics
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. KMITL
  3. Publication
  4. Effects of thermal treatment on hydrophilicity and corrosion resistance of Ti surface
Loading...
Thumbnail Image

Effects of thermal treatment on hydrophilicity and corrosion resistance of Ti surface

Author(s)
Boonrungsiman, Suwimon
Prompinit, Panida
Khemthong, Pongtanawat
Wutikhun, Tuksadon
Treethong, Alongkot
Kasamechonchung, Panita
Chanlek, Narong
Maniratanachote, Rawiwan
Horprathum, Mati
Pankiew, Apirak
Pornthreeraphat, Suppanit
Khemasiri, Narathon
Klamchuen, Annop
Date Issued
March 1, 2019
Type
Article
DOI
10.1002/sia.6580
Abstract
Surface treatment of titanium (Ti) surface has been extensively studied to improve its properties for biomedical applications, including hydrophilicity, corrosion resistance, and tissue integration. In this present work, we present the effects of thermal oxidation as surface modification method on metallic titanium (Ti). The Ti foils were oxidized at 300°C, 400°C, 500°C, and 600°C under air atmosphere for 3 hours, which formed oxide layer on Ti surface. The physicochemical properties including surface chemistry, roughness, and thickness of the oxide layer were evaluated in order to investigate how these factors affected surface hydrophilicity, microhardness, and corrosion resistance properties of the Ti surface. The results revealed that surfaces of all oxidized samples were modified by formation of titanium dioxide layer, of which morphology, phase, and thickness were changed according to the oxidized temperatures. Increasing oxidation temperature led to the formation of thicker oxide layer and phase transformation of anatase to rutile. The presence of the oxide layer helped the improvement of corrosion resistance and microhardness. The most improvement in surface roughness was found in the specimens treated at 400°C, which significantly improved surface hydrophilicity. But both surface roughness and hydrophilicity reduced when oxidized at 500°C and 600°C, suggesting that hydrophilicity was dominated by the surface roughness. In addition, this surface treatment did not reduce the biocompatibility of the metallic Ti substrates against murine osteoblasts (MC3T3).
Citation
Surface and Interface Analysis, 51(3), 308-315, 2019
Subjects

corrosion resistance

hardness

hydrophilicity

thermal oxidation

XPS and Ti surface tr...

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback