A study of an intubated tracheal air flow in a cuff-leak testing procedure

Author(s)
Sanpanich, Arthorn
Kajornpredanon, Yongyuth
Sroykham, Watchara
Petsarb, Kuson
Phairoh, Chaaim
Angkhananuwat, Wirasak
Bunluechockchai, Pimolpatra
Phasukkit, Pattarapong
Date Issued
April 23, 2018
Type
Conference Paper
DOI
10.1145/3208955.3208957
Abstract
During an artificial ventilation, an endotracheal tube (ETT) must be inserted into patient airway and following by a balloon cuff blowing in order to function as an artificial airway. However, this implementation adversely affects to a tracheal tissue and all sensitive area and probably damaging a larynx and vocal cord zone. After ETT was removed, some patients always suffering with a larynx or tracheal edema symptom in which patient airway is narrowed due to a long term pressurization by the ETT balloon cuff and causing a difficulty in his spontaneous breathing. In general, a cuff leak test is performed in order to predict a larynx or tracheal edema possibility before ETT extubation from an air volume difference between an inspiration and expiration. In this paper, an investigation of an airflow pattern and air velocity which able to imply as an air volume in the cuff leak test process is proposed in order to understand and support a prediction of the tracheal edema. The study was performed with no edema and edema case at 10, 30 and 50% of trachea internal diameter. The simulations indicate that airflow pattern shows some affects when edema region is higher than 10%. Even though, this preliminary study was intently implemented in a simple intubated trachea model, however the obtain results guide us a practical information and will be used as a basic implementation for a further study, especially in case of variety in the ETT cuff shape and pressure or in cuff less ventilation even more complication case in the near future.
Citation
ACM International Conference Proceeding Series, 76-80, 2018
Subjects

Airway airflow patter...

CFD

Cuff leak test

Larynx-trachea edema

Post-extubation strid...

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback