Repository logo
Communities & Collections
Research Outputs
Fundings & Projects
People
Statistics
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. KMITL
  3. Publication
  4. Design of a Multi-channel PD Detector for Improving Common-mode Noise Reduction Performance in Measuring and Monitoring System
Loading...
Thumbnail Image

Design of a Multi-channel PD Detector for Improving Common-mode Noise Reduction Performance in Measuring and Monitoring System

Author(s)
Tongchim, N.
Phansiri, N.
Jeenmuang, S.
Pattanadech, N.
Date Issued
January 1, 2022
Type
Conference Paper
DOI
10.23919/CMD54214.2022.9991533
Abstract
This paper deals with the design and implementation of a multi-channel partial discharge (PD) detector to improve noise reduction performance in the designed PD measuring and monitoring systems. Basically, the noise may be generated by the unexpected ground loop of the PD measuring system due to several coupling devices (CDs) being connected to the PD measuring instrument. In this paper, the signal-to-noise ratio (S/N ratio) was enhanced by using a bandpass filter and a programmable gain amplifier to filter the undesired noises and amplify the PD signal acquired in the CD. Besides, the category 7 cable (CAT7 cable) was utilized as a transmission line to transmit signals into the PD measuring instrument. This CAT7 cable with the grounded shield is comprised of 4 pairs of cables, i.e., the DC power supply cable, the PD signal cable, the test voltage signal cable, and the control signal cable used to connect between the coupling devices and the measuring instrument. Furthermore, at the input side of the measuring instrument, the Differential Receiver Amplifier was utilized to reduce the common-mode noise generated from the coupling device. Application of the proposed technique, the battery power supply, and the sophisticated isolation technique, e.g., fiber optic cable system of the active coupling device, are not needed. Furthermore, the designed PD detector was a simple and cheap price, including significant noise reduction.
Citation
2022 9th International Conference on Condition Monitoring and Diagnosis Cmd 2022, 583-587, 2022
Subjects

coupling device

partial discharge

signal-to-noise ratio...

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback