Effect of louver-perforated V-type baffles on thermal effectiveness and entropy in round tube

Author(s)
Promvonge, Pongjet
Sripattanapipat, Somchai
Suchatawat, Maturose
Nakhchi, Mahdi Erfanian
Skullong, Sompol
Date Issued
August 1, 2025
Type
Article
DOI
10.1016/j.ijthermalsci.2025.109939
Abstract
An experimental investigation was conducted to assess the influence of insertion of a louver-perforated V-type baffle (LVB) vortex generator into a consistent heat-fluxed tube on thermal performance. This study aimed to optimize thermal effectiveness to boost energy savings and reduce the heat exchanger size. The experiments focused on investigating the thermal features, as well as estimating the entropy of turbulent flow at Reynolds numbers (Re) varying between 4750 and 29,290. The LVBs were positioned in two different arrays on a supporting tape during the present experiment: “V-down” and “V-up,” with the V-apex oriented upstream and downstream, respectively, at a fixed attack angle (α = 52°). At one relative baffle height (BR = 0.3) and pitch (PR = 1.0), the LVBs dealt with six louver flapped angles (θ = 0°, 10°, 20°, 30°, 45°, and 90°) in addition to three louver-hole sizes and locations (θ1, θ2 and θ12). Comparative analysis was also conducted on data obtained from the current smooth tube. According to the findings, the louver angle θ1 = 20°, located on the baffle's trailing end, had the greatest relative Nusselt number (NuR), which was 5.9 times for V-down and 6.38 times for V-up. Furthermore, compared to the V-down and V-up solid baffles (θ = 0°), their friction losses were lessened. The V-up LVB reached its minimum value at θ1 = 20°, corresponding to the lowest Re. At θ1 = 20°, the V-up LVB attained its minimum entropy generation (S˙gen′) and maximum reduced entropy factor (SR) around 20.3. At a comparable θ1 = 20°, the maximal thermal effectiveness factor (TEF) of V-down and V-up were approximately 2.39 and 2.59, respectively. The estimation and documentation of correlations were also performed for the parameters under consideration, namely Nu, f, and TEF.
Citation
International Journal of Thermal Sciences, 214, 2025
Subjects

Heat transfer

Louvered baffle

Reduced entropy facto...

Turbulent flow

Vortex generator

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback