This paper presents the core loss mathematical model design and the prediction of core loss with PMW Inverter supply. In the procedure, the 1-phase bipolar PWM inverter supply is used to supply the Epstein test apparatus with the 0.23 mm., 0.27 mm., 0.30 mm.-thick sheet, grain oriented magnetic steel, and 0.5 mm.-thick sheet, Non oriented magnetic steel. By setting the equal maximum magnetic density for each test procedure, with 0.3, 0.6, 0.9- modulation index and 1-9 kHz inverter switching frequency, the test results are shown that the core loss by the prediction is nearly the same that by the experiment, with 0.3, 0.6, 0.9- modulation index, so this mathematical model design is more useful and can be applied to the design work in electrical machine equipment.

Description

Keywords

Iron Losses, PWM Inverter

Citation

Iet Conference Publications, 2006