Effect of graphene oxide nanoparticles on blast load resistance of steel fiber reinforced concrete

Author(s)
Jamnam, Sittisak
Maho, Buchit
Techaphatthanakon, Apisit
Ruttanapun, Chesta
Aemlaor, Peerasak
Zhang, Hexin
Sukontasukkul, Piti
Date Issued
August 8, 2022
Type
Article
DOI
10.1016/j.conbuildmat.2022.128139
Abstract
Concrete structures may occasionally be subjected to both intentional or unintentional explosions which could cause casualties and damage to properties. Advance research on protective structures are important to enhance blast resistance of materials, and to protect life and properties. This study investigated the effect of graphene oxide nanoparticles (GO) on enhancing the blast resistance of fiber reinforced cement mortar (FRM). GO in solution was incorporated in steel fiber reinforced mortar at the rate of 0, 0.025, 0.050, 0.075, and 0.100 % by weight of cement. A series of experiments were carried out consisting of 2 stages: Stage 1) workability, setting time, compressive and flexural strength, and microstructure using SEM and XRD processes, and Stage 2) blasting loading test. The optimum GO dosage giving the highest compressive and flexural strengths from the 1st stage was determined and chosen to continue on the 2nd stage (blast loading test). The blasting tests were performed on panel specimens (500mmx1000mmx60mm) using TNT weighing ½ lb. (226.7 g) with three different standoff distances of 340, 400, and 460 mm. Results from Stage 1 on both flexural and compression tests indicated an optimum GO content of 0.025% by weight of cement. The workability was found to decrease with the increasing the GO content. The SEM images also revealed that the addition of GO nanoparticles reduced the porosity in the mortar matrix. For the blasting test, three damage patterns were observed: complete flexural failure, partial damage (flexural cracking), and no major damage, depending on the standoff distance and specimen type. The addition of GO can reduce the maximum and permanent deflections of the panel under blast loading. FRM panels with GO at 0.025% tested at the standoff distance of 460 mm showed the lowest level of damage.
Citation
Construction and Building Materials, 343, 2022
Subjects

Blast loading

Blast resistance

Fiber reinforced mort...

Graphene oxide

Non-contact detonatio...

Steel fiber

TNT

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback