Experiences in nonconventional partial discharge measurement for gas-insulated substation in Thailand

Author(s)
Nganpitak, Tritod
Kunakorn, Anantawat
Klienhom, Sitthisak
Likhitsupin, Suwapich
Jariyawichai, Parinya
Pattanadech, Norasage
Date Issued
January 1, 2020
Type
Conference Paper
DOI
10.1007/978-3-030-31680-8_94
Abstract
Nowadays, nonconventional partial discharge (PD) measurement has become essential for diagnosis the high-voltage insulation condition. The nonconventional PD measurement not only uses for periodic assessment but also uses for commissioning test after transportation and installation. This paper focuses on nonconventional PD test techniques using Ultra-high frequency (UHF) sensors, acoustic sensors and light detection sensors for gas-insulated substation (GIS) commissioning test. Fundamental defects found in GIS: (1) Hopping particles (2) Fixed protrusions (3) Floating potential and (4) Voids are described. Then, explanation about how to detect such defects by using UHF, acoustic and optical methods. Afterwards, PD commissioning tests were performed with three 230 kV electricity generating authority Thailand (EGAT) GISs, i.e., Phayao EGAT GIS, Lamphun 2 EGAT GIS and North Bangkok EGAT GIS. The PD signals due to hopping particle were found by using UHF sensors at Phayao and North Bangkok EGAT GISs. The acoustic PD test technique was used in Phayao EGAT GIS to locate such particles. In case of Lamphun 2 EGAT GIS, by using UHF measurement, PD signals were found due to tracking caused by flashover on the cone insulation surface. Later, light detection sensors were used to detect the PD location. As a result of studies, its clearly guarantee the powerful accuracy and efficiency of nonconventional PD measurement by the combination of UHF and acoustic technique including light detection sensors.
Citation
Lecture Notes in Electrical Engineering, 599 LNEE, 971-982, 2020
Subjects

Acoustic method

Gas-insulated substat...

Nonconventional

Optical method

Partial discharge

UHF method

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback