Repository logo
Communities & Collections
Research Outputs
Fundings & Projects
People
Statistics
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. KMITL
  3. Publication
  4. Highly Hg2+-sensitive and selective fluorescent sensors in aqueous solution and sensors-encapsulated polymeric membrane
Loading...
Thumbnail Image

Highly Hg2+-sensitive and selective fluorescent sensors in aqueous solution and sensors-encapsulated polymeric membrane

Author(s)
Kraithong, Sasiwimon
Damrongsak, Pattareeya
Suwatpipat, Kullatat
Sirirak, Jitnapa
Swanglap, Pattanawit
Wanichacheva, Nantanit
Date Issued
January 1, 2016
Type
Article
DOI
10.1039/c5ra22977d
Abstract
Two Hg2+ chemosensors, rhodamine B hydrazide (RBH) and rhodamine 6G hydrazide (R6GH), were synthesized by a single step. In the presence of Hg2+, both of the sensors RBH and R6GH exhibited highly sensitive OFF-ON fluorescence enhancement. Importantly, the sensors showed a selective binding to Hg2+ over other common metal ions such as K+, Na+, Fe3+, Ca2+, Cu2+, Ag+ and Pb2+ in aqueous solutions. The OFF-ON fluorescence enhancement upon Hg2+ binding could be ascribed to conformational change of the spirolactam moiety of the rhodamine fluorophore through a spirolactam ring opening process. Furthermore, encapsulation of the sensors by polymeric membranes (PMMA) provided high selectivity and high sensitivity, especially for the sensors-encapsulated polymeric membrane RBH that showed an extremely low detection limit (0.2 ppb), which was 245 times lower than the sensor RBH in aqueous solution. In addition to fluorescence enhancement, the presence of Hg2+ also induced a noticeable color change from colorless to pink for the sensors dissolved in aqueous solution (10% v/v MeOH/water). The detection limits of sensor RBH and R6GH in both formats were in the range of 10-9-10-7 M of Hg2+ and were sufficient for on-site Hg2+ detection in the environmental and biological systems such as ground water, drinking water and edible fish. In particular, the extremely high sensitivity of the novel sensors-encapsulated polymeric membrane RBH could pave the way for development of a real time Hg2+ detection portable device.
Citation
Rsc Advances, 6(13), 10401-10411, 2016
Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback