Repository logo
Communities & Collections
Research Outputs
Fundings & Projects
People
Statistics
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. KMITL
  3. Publication
  4. Robust power oscillation damper design for DFIG-based wind turbine based on specified structure mixed H2/H∞ control
Loading...
Thumbnail Image

Robust power oscillation damper design for DFIG-based wind turbine based on specified structure mixed H2/H∞ control

Author(s)
Surinkaew, Tossaporn
Ngamroo, Issarachai
Date Issued
January 1, 2014
Type
Article
DOI
10.1016/j.renene.2013.11.060
Abstract
As the integration of a doubly fed induction generator (DFIG)-based wind power generation into power systems tends to increase significantly, the contribution of DFIG wind turbine is highly expected. Since the active and reactive power outputs of DFIG can be independently modulated, the stabilizing effect of DFIG on the inter-area power system oscillation is a challenging issue. This paper proposes a new robust control design of power oscillation damper (POD) for a DFIG-based wind turbine using a specified structure mixed H2/H∞ control. The POD structure is a practical 2nd-order lead-lag compensator with single input. Normally, H∞ control mainly enforces the closed-loop stability while noise attenuation or regulation against random disturbances is expressed in H2 control. As a result, the mixed H2/H∞ control gives a powerful multi-objective control design so that both closed-loop stability and performance of designed controller can be guaranteed. Here, the linear matrix inequality is applied to formulate the optimization problem of POD based on a mixed H2/H∞ control. The POD parameters are optimized so that the performance and robustness of the POD against system disturbances and uncertainties are maximal. The firefly algorithm is automatically applied to solve the optimization problem. Simulation study in a two-area four-machine interconnected power system shows that the DFIG with robust POD is superior to conventional POD in terms of stabilizing effect as well as robustness against various power generating and loading conditions, unpredictable network structure, and random wind patterns. © 2013.
Citation
Renewable Energy, 66, 15-24, 2014
Subjects

Doubly fed induction ...

Firefly algorithm

Inter-area oscillatio...

Linear matrix inequal...

Mixed H2/H∞ control

Power oscillation dam...

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback