Abstract
This paper presents characteristics of turbulent convective heat transfer in a tube fitted with wire coil turbulators. Two different wire coils are introduced: (1) with typical/uniform coil pitch ratio (CR) and (2) with periodically varying three-coil pitch ratio. Various uniform coil pitch ratios (CR = 4, 6, and 8) and two periodically varying coil pitch ratios, the D-coil (decreasing three-coil pitch ratio arrangement) and DI-coil (decreasing/ increasing three-coil pitch ratio arrangement), are experimentally investigated in a uniform heat flux tube. The experiments are performed for turbulent flows with Reynolds numbers ranging between 4500 and 20,000. All of the experimental results are compared with those obtained from using the plain tube, while the thermal performance factor is evaluated under an equal pumping power constraint. The experimental results show that the use of the tube fitted with all wire coils leads to an advantage on the basis of heat transfer enhancement over the plain tube with no insert. It is also observed that the uniform-pitch wire coil with higher coil pitch ratio (CR = 8) gives a higher thermal performance factor compared to ones with lower coil pitch ratios (CR = 4 and 6). In addition, for two periodically varying coil pitch ratios, the DI-coil performs with better heat transfer rate than the uniform-pitch ratio (CR = 6) and the D-coil for all Reynolds number ranges studied. The empirical correlations developed in terms of coil pitch ratios (CR), varying coil pitch ratios (D-coil and DI-coil), and Reynolds number are fitting the experimental data within plus or minus 3% and 5% for Nusselt number (Nu) and friction factor (f), respectively. The results of the thermal performance factor for various CR, D-coil, and DI-coil values are also determined. Copyright © Taylor and Francis Group, LLC.
Citation
Heat Transfer Engineering, 32(11-12), 957-967, 2011
Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback