Repository logo
Communities & Collections
Research Outputs
Fundings & Projects
People
Statistics
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. KMITL
  3. Publication
  4. Thermal behaviors and flow profiles in a square channel fitted with X–V modified ribs: A numerical analysis
Loading...
Thumbnail Image

Thermal behaviors and flow profiles in a square channel fitted with X–V modified ribs: A numerical analysis

Author(s)
Boonloi, Amnart
Jedsadaratanachai, Withada
Date Issued
September 1, 2023
Type
Article
DOI
10.1016/j.csite.2023.103282
Abstract
A novel design of “X–V rib” turbulators is proposed to improve fluid blending and to perturb thermal boundary layer (TBL) in a heat exchanger (HX) duct. Better fluid blending and more highly disturbed TBL are the two important factors for the improvement of HX performance. Effects of X–V rib geometrical parameters including rib height ratios (b/H = 0.05–0.20), rib arrangements (V-tip pointing upstream called “V-Upstream (VU)” and V-tip pointing downstream called “V-Downstream (VD)”) and rib types (I, II and III) on air stream and thermal mechanisms are numerically investigated in a 3D model. The numerical model is solved with the finite volume method (a commercial code) and a commercial program. Laminar air flow (inlet conditions with Re = 100–2000) is a selected range of the present investigation. Firstly, the created numerical model for the ribbed duct is validated with two significant topics: 1. Plain duct validation and 2. Optimum grid elements (grid independence). The validated results show that the ribbed-duct model has great reliability to simulate air stream and thermal characteristics. According to the numerical results, the disturbed TBL is obviously found in all rib types. Moreover, it is observed that the core flow disturbance occurs and improves fluid blending. The outcomes from the present investigation point out that the knowledge about flow structure and thermal mechanism are important guidelines for the development of vortex turbulators and HX improvement. For the thermal assessments, it is found that the best Nusselt number ratio (Nu/Nu0) is 11.80 for the type III X–V rib with b/H = 0.20 in the VD-direction. Additionally, the maximum thermal enhancement factor within our investigated range is 3.48 at Re = 2000, b/H = 0.20, type II X–V rib in the VU-direction.
Citation
Case Studies in Thermal Engineering, 49, 2023
Subjects

Numerical analysis

Passive technique

Thermal performance

Vortex turbulator

X-V rib

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback