Repository logo
Communities & Collections
Research Outputs
Fundings & Projects
People
Statistics
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. KMITL
  3. Publication
  4. Transfer Learning for Classifying Motor Imagery EEG: A Comparative Study
Loading...
Thumbnail Image

Transfer Learning for Classifying Motor Imagery EEG: A Comparative Study

Author(s)
Limpiti, Tulaya
Seetanathum, Kornthum
Sricom, Natchaya
Puttarak, Nattakan
Date Issued
January 1, 2021
Type
Conference Paper
DOI
10.1109/BMEiCON53485.2021.9745213
Abstract
Motor imagery (MI) is the cognitive process when a person imagines performing a specific movement of their body. The corresponding electroencephalographic (EEG) signals can be measured externally to the head using scalp electrodes. Such signals have been applied in healthcare brain-computer-interface (BCI) systems, for example, motor rehabilitation and prosthetics control. These systems convert different MI EEG input signals to directives, so their performances depend on the efficiency of the embedded signal classification algorithm. In this paper we investigate the effectiveness of transfer learning in classifying the MI EEG data. The Continuous Wavelet Transform (CWT) is used to construct the scalograms, which serve as the inputs to the deep learning structure. The efficacies of five pre-trained networksAlexNet, ResNet18, ResNet50, InceptionV3 and ShuffleNet-are evaluated on the BCI competition IV data set 2a. Binary (left hand vs. right hand) and four-class (left hand, right hand, both feet, and tongue) classifications are trained and tested using fivefold cross validation. The result indicates that using the CWT with transfer learning models provides very high classification accuracies. The ResNet18 network achieves the best accuracies in both cases at 95.03±2.95% and 91.86±2.90%, respectively. In addition, we examine the effect of different time-frequency features on the classification performance by comparing the scalogram of the CWT and the spectogram of the Short-Time Fourier Transform (STFT) as the inputs. It is found that the CWT is the preferred choice as it is superior to the STFT.
Citation
Bmeicon 2021 13th Biomedical Engineering International Conference, 2021
Subjects

continuous wavelet tr...

deep learning

electroencephalogram

motor imagery

scalogram

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback