Simple flow system with in-line gas-diffusion unit for determination of ethanol employing hypsochromic shift of visible absorbance band of methyl orange

Author(s)
Ratanawimarnwong, Nuanlaor
Sinpun, Montatip
Chankaw, Panuwat
Choengchan, Nathawut
Nacapricha, Duangjai
Date Issued
January 1, 2020
Type
Article
DOI
10.1016/j.talanta.2019.120234
Abstract
The effect of solvent composition on the uv–visible spectrum of methyl orange was investigated for application to the quantitative determination of ethanol. At fixed pH, there was a hypsochromic shift of the absorbance band of methyl orange with increasing ethanol concentration. Using acetate buffer at pH 3.40 the change of absorbance at 530 nm of a solution of methyl orange containing known concentrations of standard ethanol was measured to provide a calibration curve. In order to apply this method to the analysis of alcoholic samples, such as distilled spirits, blended spirits and liquid herbal medicines, a simple gas-diffusion unit coupled with flow system was employed to separate the ethanol from sample matrices. Using the gas diffusion-flow system and employing an evaporation time of 2 min, a linear calibration range of 5–45% (v/v) ethanol was achieved ((ΔA = (0.0078 ± 0.0002)x(ethanol, %(v/v)) + (0.040 ± 0.005)), r2 = 0.998). The limit of detection (3σ blank/slope) was 2.23% (v/v). The developed gas diffusion-flow system was applied to the analysis of colorless distilled spirits, yellow blended spirits and dark brown herbal medicines that are available in the local markets of Bangkok, Thailand. Validation of the method was carried out by comparing the results with analysis using gas chromatography. There was no statistically significant difference at the 95% confidence level for all alcoholic samples analyzed.
Citation
Talanta, 206, 2020
Subjects

Ethanol

Gas diffusion-flow sy...

Methyl orange

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback