Temperature Compensation for Transformer-type Transducer

Author(s)
Songsuwankit, Kanoknuch
Riewruja, Vanchai
Watanachaturaporn, Pakorn
Rerkratn, Apinai
Petchmaneelumka, Wandee
Date Issued
January 1, 2021
Type
Article
DOI
10.18494/sam.2021.3421
Abstract
A novel technique to compensate the temperature effect of a transformer-type transducer is proposed in this paper. The effect of the ambient temperature on the transformer-type transducer is investigated from a primary-winding current. The advantage of the proposed technique is that the temperature effect is compensated without requiring a temperature sensor, making it suitable for applications in robotic and automation systems operated in harsh environments. The primary-winding current of the transducer is generated using a second-generation current conveyor (CCII). The excitation signal of the transformer-type transducer is driven by the CCII and the current flowing through the primary winding is transferred to an output signal of the CCII. The deviation of the primary-winding current due to the temperature effect is evaluated from the output signal of the CCII. The temperature effect on the transducer is manipulated by a closed-loop principle using a subtract-and-sum action instead of a traditional proportional-plusintegral action to eliminate the deviation of the primary-winding current. Therefore, the temperature effect on the transducer is compensated. A linear variable differential transformer (LVDT) is used to demonstrate the proposed technique, whose performance is discussed in detail and confirmed experimentally. All devices used in this experiment are commercially available. Experimental results show that the measured error of the output signal from the LVDT at 70 C can be reduced from 6.2% without temperature compensation to 0.06% by using the proposed technique, which has the advantages of a low cost, simple configuration, and high performance.
Citation
Sensors and Materials, 33(12), 4283-4296, 2021
Subjects

CCII

LVDT

Opamp

Resolver

Temperature compensat...

Transformer-type tran...

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback