Repository logo
Communities & Collections
Research Outputs
Fundings & Projects
People
Statistics
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. KMITL
  3. Publication
  4. Ultratrace Detection of Nickel(II) Ions in Water Samples Using Dimethylglyoxime-Doped GQDs as the Induced Metal Complex Nanoparticles by a Resonance Light Scattering Sensor
Loading...
Thumbnail Image

Ultratrace Detection of Nickel(II) Ions in Water Samples Using Dimethylglyoxime-Doped GQDs as the Induced Metal Complex Nanoparticles by a Resonance Light Scattering Sensor

Author(s)
Pimsin, Nipaporn
Kongsanan, Niradchada
Keawprom, Chayanee
Sricharoen, Phitchan
Nuengmatcha, Prawit
Oh, Won Chun
Areerob, Yonrapach
Chanthai, Saksit
Limchoowong, Nunticha
Date Issued
June 15, 2021
Type
Article
DOI
10.1021/acsomega.1c00190
Abstract
This study aimed to synthesize dimethylglyoxime (DMG) (N-source)-doped graphene quantum dots (N-GQDs) via simultaneous pyrolysis of citric acid and 1.0% (w/v) DMG. The maximum excitation wavelength (λmax, ex = 380 nm) of the N-GQD solution (49% quantum yield (QY)) was a red shift with respect to that of bare GQDs (λmax, ex = 365 nm) (46% QY); at the same maximum emission wavelength (λmax, em = 460 nm), their resonance light scattering (RLS) intensity peak was observed at λmax, ex/em = 530/533 nm. FTIR, X-ray photoelectron spectroscopy, XRD, energy-dispersive X-ray spectroscopy, and transmission electron microscopy analyses were performed to examine the synthesized materials. The selective and sensitive detection of Ni2+ using the RLS intensity was performed at 533 nm under the optimum conditions consisting of both 25 mg L-1 N-GQDs and 2.5 mg L-1 DMG in the ammonium buffer solution of pH 9.0. The linearity of Ni2+ was 50.0-200.0 μg L-1 with a regression line, y = 5.031x - 190.4 (r2 = 0.9948). The limit of detection (LOD) and the limit of quantitation (LOQ) were determined to be 20.0 and 60.0 μg L-1, respectively. The method precision expressed as % RSDs was 4.90 for intraday (n = 3 × 3) and 7.65 for interday (n = 5 × 3). This developed method afforded good recoveries of Ni2+ in a range of 85-108% when spiked with real water samples. Overall, this innovative method illustrated the identification and detection of Ni2+ as a DMG complex with N-GQDs, and the detection was highly sensitive and selective.
Citation
ACS Omega, 6(23), 14796-14805, 2021
Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback