Repository logo
Communities & Collections
Research Outputs
Fundings & Projects
People
Statistics
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. KMITL
  3. Publication
  4. A ninety-six well plate as headspaces with moist starch indicator paper as a cover for the determination of ascorbic acid by iodate oxidation and formation of volatile iodine
Loading...
Thumbnail Image

A ninety-six well plate as headspaces with moist starch indicator paper as a cover for the determination of ascorbic acid by iodate oxidation and formation of volatile iodine

Author(s)
Nawalohakul, Thichaphat
Charoenjiraroj, Pannarat
Chantiwas, Rattikan
Wilairat, Prapin
Praditweangkum, Wiboon
Date Issued
February 21, 2022
Type
Article
DOI
10.1039/d1ay02050a
Abstract
This work presents the use of a 96-well plate as headspaces for the determination of ascorbic acid in samples loaded in the 96-well plate. Ascorbic acid in the sample is oxidized to iodide by the addition of excess acidic iodate solution into the well. The iodide is further oxidized by the remaining iodate to molecular iodine. A single sheet of moist starch indicator paper is immediately placed over the 96-well plate after the addition of the iodate with the moisture forming a gas seal. The iodine gas in each well diffuses through the headspace to react with the starch paper producing circular areas of a colored starch-iodine complex. After 15 min the indicator paper is scanned, and the digital images of the complex are analyzed by using ImageJ software to obtain blue intensity values. The precision of the intensity values from 12 wells containing 20 μL of 2.84 mM standard ascorbic acid is <2% relative standard deviation. Optimal conditions for detection were investigated, including the starch concentration, the acidic iodate reagent, and the measurement time. The linear calibration range of ascorbic acid is 0.284-2.84 mM, based on the plot of concentration vs. -log(reflectance). The coefficient of determination (r2) is >0.998. Samples of fruit juice and dietary supplements were analyzed for their ascorbic acid contents. The results obtained from the headspace reflectance method are not statistically different from values obtained from the titration method using paired t-tests (α = 0.05). This journal is
Citation
Analytical Methods, 14(7), 741-749, 2022
Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback