Abstract
Diabetes is one of the chronic diseases with an increasing number of patients every year. Therefore, blood glucose level (BGL) is an essential health information for diagnosis and management of diabetes. Commonly, the BGL is usually measured invasively by taking blood samples, which can cause pain or discomfort to the patients. Our paper aims to design and develop a low-cost, low-computational non-invasive blood glucose measuring system using optical technique. The proposed system consists of a hardware for measuring photoplethysmogram (PPG). The PPG signal is subsequently analyzed to estimate the corresponding BGL, which is sent wirelessly to be stored in a database and displayed on an Android application. The application recommends the appropriate dosage of insulin injection based on the type of users and their diets. The report of historical blood glucose levels in the database can also be generated for further medical examination.Three PPG features, namely peak-to-peak amplitude, maximum amplitude, and standard deviation of signal amplitude, have the strongest correlations to the BGL. We investigate three regression models for estimating the BGL from these PPG parameters. The robustness of the system is assessed using cross validations. The average root mean squares error (RMSE) for three-fold cross-validations are 17.38, 16.76, and 16.39 mg/dL for simple linear regression, principal component regression, and partial least squares regression, respectively. The RMSEs from leave-one-out cross validation are approximately 12 mg/dL, with partial least squares regression model having the best accuracy. Furthermore, the results from Clarke Error Grid Analysis indicate that the system can be implemented with any of the three models for practical usage.
Citation
Bmeicon 2023 15th Biomedical Engineering International Conference, 2023
Subjects

Blood glucose level

diabetes

linear regression

partial least squares...

photoplethysmography

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback