Seasonal Field Calibration of Low-Cost PM2.5 Sensors in Different Locations with Different Sources in Thailand

Author(s)
Dejchanchaiwong, Racha
Tekasakul, Perapong
Saejio, Apichat
Limna, Thanathip
Le, Thi Cuc
Tsai, Chuen Jinn
Lin, Guan Yu
Morris, John
Date Issued
March 1, 2023
Type
Article
DOI
10.3390/atmos14030496
Abstract
Low-cost sensors (LCS) have been increasingly deployed to monitor PM2.5 concentrations. More than 1500 LCS have been installed in Thailand to increase public awareness of air quality. However, performance of these sensors has not been systematically investigated. In this study, PM2.5 LCS were co-located next to a PM2.5 federal equivalent method (FEM) reference instrument at three Thai locations—in the north, center and northeast. We evaluated the performance of a PM2.5 LCS (PMS7003, Plantower) to understand the key factors affecting performance, including emission sources, relative humidity, temperature and PM2.5 concentration. Low PM concentration and high humidity levels had a significant impact on performance. Sensors in a high traffic emission area showed low correlation. The unadjusted PM2.5 LCS performance varied with locations. Errors were mainly observed at low concentrations. They significantly underestimated concentrations in congested urban environments. After calibration, accuracy was improved with multiple regression models. The performance of sensors only at Chiang Mai (CM) during the dry season and Ubon Ratchathani (URT) during the dry and wet seasons were acceptable with coefficient of variation: 5.8 ± 4.7–6.8 ± 5.0%, slope: 0.829–0.945, intercept: 1.12–5.49 µg/m3, R2: 0.880–0.934 and RMSE: 4.3–5.1 µg/m3. In the congested area in Bangkok (BKK), they underestimated concentrations of small particles.
Citation
Atmosphere, 14(3), 2023
Subjects

emission sources

long-term study

low-cost PM2.5 sensor...

Southeast Asia

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback