Repository logo
Communities & Collections
Research Outputs
Fundings & Projects
People
Statistics
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. KMITL
  3. Publication
  4. Simple Empirical Relation for an Evacuated-Tube Solar Collector Performance Prediction from Solar Intensity
Loading...
Thumbnail Image

Simple Empirical Relation for an Evacuated-Tube Solar Collector Performance Prediction from Solar Intensity

Author(s)
Pongboriboon, Nattapat
Wu, Wei
Chandra-ambhorn, Walairat
Wongpromrat, Patthranit
Bumrungthaichaichan, Eakarach
Date Issued
September 1, 2023
Type
Article
DOI
10.3390/en16176256
Abstract
In this paper, the effect of solar intensity on the heat pipe tip temperature in a heat pipe type—evacuated-tube solar collector (HP-ETSC) was investigated. A simple relation was proposed, relating the solar intensity to the heat pipe tip temperature generated from the experimental data. This simple empirical relation was applied in a set of heat transfer equations derived to predict the heating medium temperature at the manifold outlet of the evacuated-tube solar collector. The calculated results corresponding to two types of heating medium, i.e., palm oil and water, were compared with experimental results from the literature. The results show that the average error was 6.41% for the case of palm oil and 4.66% for the case of water. Based on the case of water as a heating medium fluid, it was found that the flow rate of the heating medium fluid affected the accuracy of prediction, as the percentage error increased with the heating medium flow rate. The maximum percentage error increased from only 1.83% for a water inlet flowing at a Reynolds number of about 2.4 × 103 to 15.23% for a water flow rate at a Reynolds number of about 2.6 × 104. The correction factor was added into the correlation to predict the heat transfer coefficients of heating medium fluids. With this correction factor, the maximum error could be reduced from 11.78% to 7.29% for the palm oil case and from 15.23% to 5.57% for the water case. The average errors corresponding to palm oil and water cases could be reduced to 0.74% and 1.26%, respectively.
Citation
Energies, 16(17), 2023
Subjects

empirical relation

evacuated-tube solar ...

solar intensity

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback