Repository logo
Communities & Collections
Research Outputs
Fundings & Projects
People
Statistics
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. KMITL
  3. Publication
  4. Evaluating limit of detection and quantification for higher heating value and ultimate analysis of fast-growing trees and agricultural residues biomass using NIRS
Loading...
Thumbnail Image

Evaluating limit of detection and quantification for higher heating value and ultimate analysis of fast-growing trees and agricultural residues biomass using NIRS

Author(s)
Shrestha, Bijendra
Shrestha, Zenisha
Posom, Jetsada
Sirisomboon, Panmanas
Shrestha, Bim Prasad
Date Issued
October 9, 2023
Type
Article
DOI
10.14456/easr.2023.63
Abstract
Accurate non-destructive assessment of biomass energy properties is essential for optimizing its use as an alternative fuel. In this study, 200 biomass samples were used to determine higher heating value (HHV) and 120 biomass samples for analyzing ultimate analysis parameters using near-infrared spectroscopy within the full wavenumber range of 12489.48 – 3594.87 cm-1. The samples were grounded, and five different types of partial least squares regression (PLSR) models were developed using traditional preprocessing, multi-preprocessing (MP) with 5 range, MP with 3 range, genetic algorithm, and successive projection algorithm. Limit of detection (LOD) and quantification (LOQ) were calculated using the best-performing model among five different PLSR models for HHV in kJ/kg, as well as the weight percentage (wt.%) of carbon (C), oxygen (O), hydrogen (H), and nitrogen (N). The LOD and LOQ for HHV were calculated as 622.42 kJ/kg and 1886.13 kJ/kg, respectively. Additionally, LOD and LOQ for ultimate analysis parameters, including C, O, H, and N were calculated as: 3.24 weight percentage (wt.%) and 9.81 wt.% for C, 2.04 wt.% and 6.18 wt.% for O, 0.35 wt.% and 1.05 wt.% for H, and 0.22 wt.% and 0.68 wt.% for N. The LOD and LOQ values for HHV, C, O, and H were lower than the minimum reference values used for model development, demonstrating the models’ high sensitivity and potential to reliably detect and precisely quantify these parameters. However, the LOD and LOQ values exceeded the minimum reference value used during model development for the N, indicating that the selected models have certain limitations in assessing the N content in biomass. The sample range should be expanded for wt.% of N to enhance the model’s performance, surpassing the LOD and LOQ values. This will improve the overall sensitivity of the model for reliable detection and quantification of N content in biomass samples.
Citation
Engineering and Applied Science Research, 50(6), 612-618, 2023
Subjects

Biomass

Limit of detection

Limit of quantificati...

Near-infrared spectro...

Partial least squares...

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback