Calibration of Bi-prism Stereo Systems: A Model Free Approach

Author(s)
Dissanayaka, Supun
Sooraksa, Pitikhate
Kaitwanidvilai, Somyot
Morris, John
Date Issued
July 1, 2024
Type
Article
DOI
10.55003/ETH.410302
Abstract
A simple stereo system can be constructed from a single camera using a prism in the optical path to provide the required two views of a system. The simplicity of these systems has several advantages, particularly if the target is an underwater robot, where compact size and ability to seal the optical components are key factors. However, dispersion by the prism, in addition to the lens distortion, makes calibration challenging. By using a model-free approach, we were able to calibrate a prism-based stereo system effectively. We also aimed to use readily available 45° prisms, which present significant dispersion in the system, but retain simplicity and reduce cost, compared to custom low angle prisms. Modern LEDs provide high intensity, low bandwidth light sources and we used a set of three sources, roughly centered on the RGB channels of a readily available commercial camera. Our system used a circular target pattern covering the binocularly visible region in the scene and collected sets of images at known distances, using three separate light sources. From these images, we generated two look-up tables, one for each pixel in the image and a disparity derived by matching corresponding points, Cp(u,v,du), which has three dimensions, and another look-up table, which has a single dimension, Cz(z), so are not quite large, and not beyond the memory capability of even small modern camera systems, but provide fast, O(1), lookup times, suitable for real-time systems. Our calibration strategy enables a simple stereo system built from a single camera to measure depths in a scene: the single camera requires no electronic synchronization and is built from a single, inexpensive, and readily available optical component – a right-angle prism.
Citation
Engineering and Technology Horizons, 41(3), 2024
Subjects

Bi-prism

Calibration

Monochromatic

Stereo

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback