Repository logo
Communities & Collections
Research Outputs
Fundings & Projects
People
Statistics
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. KMITL
  3. Publication
  4. Design and Implementation of a High-Field NdFeB Magnet System for Investigating the Spin Seebeck Effect
Loading...
Thumbnail Image

Design and Implementation of a High-Field NdFeB Magnet System for Investigating the Spin Seebeck Effect

Author(s)
Nachaithong, Theeranuch
Wongjom, Chalothon
Samransuksamer, Benjarong
Phumying, Santi
Pongophas, Ekkarat
Maiaugree, Wasan
Pijitrojana, Wanchai
Horprathum, Mati
Chananonnawathorn, Chanunthorn
Pinitsoontorn, Supree
Moontragoon, Pairot
Ramamoorthy, Harihara
Somphonsane, Ratchanok
Kalasuwan, Pruet
Wongjom, Poramed
Date Issued
January 1, 2025
Type
Article
DOI
10.1109/TIM.2025.3545533
Abstract
The generation of pure spin current through thermal gradients, known as the spin Seebeck effect (SSE), has garnered significant interest in spintronics. In this study, we design and construct a permanent magnetic instrument setup to generate a variable external magnetic field using NdFeB permanent magnets to observe the SSE. The experimental setup is composed of three crucial components: the magnetic field, the temperature gradient, and electronic control systems. Si/yttrium iron garnet (YIG)/platinum (Pt) and Si/nickel (Ni) samples, prepared via sputtering techniques, were utilized for standard calibration purposes. The results show that the external magnetic field produced by NdFeB varies with the gap distance between the two magnetic poles, following an exponential decrease in field strength with increasing gap distance. The magnetic field at the center can be adjusted from ±20 to ±5000 Oe. The temperature gradient stabilizes after approximately 10 min, with a temperature difference ( ΔT ) between the heated and cooled sides ranging from 0 to 30 K. For instrument testing, we performed magnetic field and angle-dependent measurements on Si/YIG/Pt and Si/Ni samples. The results indicate that the magnetic field dependence of the permanent magnet instrument (PMI) does not exhibit the voltage loop switching seen with an alternative magnetic coil (AMC) but shows analogous behavior at high magnetic fields. Moreover, the angle dependence of both PMI and AMC yielded comparable results. In conclusion, our PMI setup procedures effectively facilitate the observation of the SSE.
Citation
IEEE Transactions on Instrumentation and Measurement, 74, 2025
Subjects

Anomalous Nernst effe...

inverse spin Hall eff...

NdFeB

permanent magnet

spin caloritronics

spin Seebeck effect (...

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback