Repository logo
Communities & Collections
Research Outputs
Fundings & Projects
People
Statistics
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. KMITL
  3. Publication
  4. Analysis of Indoor PM2.5 Contaminants Based on Outdoor Wind Velocity Through Different Infiltration Types
Loading...
Thumbnail Image

Analysis of Indoor PM2.5 Contaminants Based on Outdoor Wind Velocity Through Different Infiltration Types

Author(s)
Oo, Ghaim Man
Kotmool, Komsilp
Mongkolwongrojn, Mongkol
Date Issued
January 1, 2025
Type
Article
DOI
10.1155/je/4145524
Abstract
Nowadays, indoor PM2.5 concentrations have become a significant factor affecting indoor air quality (IAQ) and a major public concern, particularly with the rise of haze in Thailand and globally, as PM2.5 can penetrate human lungs. This research analyzes the dispersion of PM2.5 from outdoors to indoors using a fluid dynamics simulation framework that combines the Eulerian approach for continuous flow, the Lagrangian approach for particulate matter dispersion, and the RNG k-ε turbulent model for airflow. The study is aimed at protecting indoor environments from harmful exposure to PM2.5 from outdoor contaminants and improving IAQ. Primarily, three different infiltration types and shapes are studied to determine the minimum optimal positive room pressure, based on the impact of ambient wind velocity on indoor PM2.5 concentrations from outdoor pollutants. A minimum optimal pressure of 3.6 Pa and 27 air changes per hour (ACH) is sufficient to achieve a PM2.5-free indoor environment for all infiltration models. Furthermore, higher wind speeds can reduce indoor PM2.5 concentrations due to the increased momentum of particles. This research technique is implemented in the practical field study conducted within the laboratory room of the 55-Year Chalermprakiat Building. As a result, the investigated room, with an infiltration area of 0.06 m2 and a rate of 0.0036 m3/s, will be certified as a clean room by achieving an optimal minimum pressure of approximately 0.01 Pa. This research will help achieve cleaner and safer indoor environments for any building by leveraging the optimal minimum pressure of cleanroom technology, provided that the infiltration rate and ambient wind velocity are accurately determined.
Citation
Journal of Engineering United Kingdom, 2025(1), 2025
Subjects

air pollution

IAQ

infiltration types

Lagrangian approach

optimal positive pres...

wind velocity

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback