Repository logo
Communities & Collections
Research Outputs
Fundings & Projects
People
Statistics
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. KMITL
  3. Publication
  4. Collapse prevention of pre-stressed electric transmission poles using glass fiber reinforced polymers
Loading...
Thumbnail Image

Collapse prevention of pre-stressed electric transmission poles using glass fiber reinforced polymers

Author(s)
Parichatprecha, Rattapoohm
Rodsin, Kittipoom
Suthasupradit, Songsak
Mehmood, Tahir
Nawaz, Adnan
Date Issued
July 1, 2025
Type
Article
DOI
10.1016/j.cscm.2024.e04110
Abstract
Natural hazards such as strong winds, typhoons, and earthquakes have caused massive economic losses in the form of damage to residential and life-line structures. Electric transmission infrastructures are life-line structures susceptible to severe damage under lateral loads like wind and earthquakes. This study focused on vulnerability assessment and measures to reduce the expected damage to the prestressed electric transmission poles under lateral loads. The Glass Fiber Reinforced Polymer (GFRP) sheet is selected as a strengthening material because the fiber cost is affordable but still has acceptable high tensile strength. A full-scale 12-meter-long prestressed transmission pole was tested under reversed cyclic lateral loading. Furthermore, another specimen strengthened with the GFRP sheet was tested to quantify the effectiveness of this technique. The experimental results show significant improvement in the lateral response behavior of prestressed poles in terms of lateral drift capacity, ductility, and energy dissipation characteristics. The GFRP-strengthened specimen exhibited a significantly enhanced lateral drift capacity (more than 100 %) compared to the control specimen. The performance of GFRP in preventing the collapse of a full-scale transmission pole is proved experimentally in this study. Finally, a numerical model based on the fiber modeling concept was also implemented in the open-source platform OpenSees to simulate the observed hysteretic behavior for strengthened and unstrengthened prestressed electric transmission poles. The application of this strengthening method is shown to be very practical for collapse prevention of existing PC poles both in terms of performance and budget.
Citation
Case Studies in Construction Materials, 22, 2025
Subjects

Electric transmission...

Lateral loading

Lifeline infrastructu...

OpenSees

Prestressed

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback