Repository logo
Communities & Collections
Research Outputs
Fundings & Projects
People
Statistics
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. KMITL
  3. Publication
  4. Flexible thermoelectric cooler with optimized fill factor and radiative cooling integration for energy-efficient wearable thermal management
Loading...
Thumbnail Image

Flexible thermoelectric cooler with optimized fill factor and radiative cooling integration for energy-efficient wearable thermal management

Author(s)
Gobpant, Jakrit
Sakulkalavek, Aparporn
Sriniratkul, Pannarai
Sa-I, Saowanee
Rudradawong, Chalermpol
Tian, Jianghan
Nguyen, Vien Quoc
Ono, Takahito
Van Toan, Nguyen
Date Issued
December 1, 2025
Type
Article
DOI
10.1016/j.susmat.2025.e01742
Abstract
The growing demand for skin-interfaced electronics in health monitoring, sports, and personal comfort highlights the need for compact, energy-efficient, and conformable cooling systems. However, existing thermoelectric coolers (TECs) are rigid, bulky, and power-intensive, making them unsuitable for wearable applications. To address this limitation, we present a flexible thermoelectric cooler (FTEC) with a compact footprint of 40 × 40 × 2.26 mm3, featuring discrete p- and n-types thermoelectric leg arrays with systematically varied fill factors (FF = 9 %, 16 %, 25 %, and 36 %). Optimization revealed that the 16 % FF configuration provides the most energy-efficient architecture, achieving a cold-side temperature of −5.9 °C and a coefficient of performance (COP) of 3.25 at 6 W input, while balancing cooling capacity and electrical loss. To improve heat dissipation without increasing bulk, ultrathin graphite and radiative cooling (RC) layers were integrated. Three configurations, including baseline (no thermal layer), graphite-enhanced, and RC-enhanced FTECs, were systematically evaluated. Under ambient conditions (33 °C), the RC- enhanced FTEC maintained a cold-side temperature of approximately 23 °C for 6 h during low-current operation of 0.3 A. Beyond intrinsic performance, the optimized FTEC was benchmarked against both commercial rigid TEC modules and state-of-the-art flexible TECs. Compared to widely used Peltier devices (TEC1–12705 and TEC1–12710), our FTEC achieved comparable ΔT with nearly 65 % lower power consumption, owing to fill factor optimization and RC-enhanced heat rejection. Mechanical flexibility was validated through bending tests, confirming both thermal and electrical stability. Finally, integration with an ESP32-based proportional–integral–derivative (PID) control system enabled real-time wearable cooling, successfully reducing skin temperature from 33 °C to 31 °C in on-body trials. This work demonstrates.
Citation
Sustainable Materials and Technologies, 46, 2025
Subjects

Fill factor optimizat...

Flexible thermoelectr...

Low-power cooling

Radiative cooling

Wearable cooling

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback