Repository logo
Communities & Collections
Research Outputs
Fundings & Projects
People
Statistics
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. KMITL
  3. Publication
  4. Influence of Wired Twisted Tape on Heat Transfer Enhancement, Friction Factor and Thermal Performance Behaviors in a Heat Exchanger Tube
Loading...
Thumbnail Image

Influence of Wired Twisted Tape on Heat Transfer Enhancement, Friction Factor and Thermal Performance Behaviors in a Heat Exchanger Tube

Author(s)
Lin, Jianyu
Laphirattanakul, Ponepen
Bhattacharyya, Suvanjan
Thapmanee, Piphatpong
Wongcharee, Khwanchit
Kaewkosum, Pichit
Chokphoemphun, Suriya
Eiamsa-ard, Smith
Date Issued
March 1, 2026
Type
Article
DOI
10.3390/eng7030128
Abstract
This study experimentally investigates the thermal–hydraulic performance of heat exchanger tubes fitted with wired twisted tapes, with particular emphasis on the effects of the hole spacing-to-width ratio (s/W) and edge margin-to-width ratio (e/W). Experiments were conducted over a Reynolds number range of 6000–20,000, and the results were compared with those of plain tubes and tubes equipped with conventional twisted tapes. The findings revealed that the incorporation of wires significantly enhanced heat transfer due to the combined action of longitudinal eddies generated by wire protrusions and swirling flow induced by the twisted tape. At identical Reynolds numbers, tubes with a smaller hole spacing (s/W = 0.16) exhibited superior heat transfer performance, achieving Nusselt number enhancements of up to 107.7% relative to plain tubes and 51.6% relative to conventional twisted tapes. Similarly, reducing the edge margin ratio intensified near-wall eddies and further disrupted the boundary layer. The friction factor was found to increase with decreasing hole spacing and edge margin, primarily due to additional flow obstructions and enhanced near-wall shear stresses. For wired twisted tapes with s/W = 0.16, the friction factor reached nearly six times that of a plain tube. Despite this penalty, the thermal performance factor (TPF) remained favorable, with values of up to 1.2, indicating that the heat transfer benefits outweighed the corresponding pressure losses.
Citation
Eng, 7(3), 2026
Subjects

heat exchanger tube

heat transfer

thermal performance

wired twisted tape

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback