Repository logo
Communities & Collections
Research Outputs
Fundings & Projects
People
Statistics
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. KMITL
  3. Publication
  4. Experimental and numerical evaluations of thermal performance in heat exchange channel with punched V-type delta-winglets
Loading...
Thumbnail Image

Experimental and numerical evaluations of thermal performance in heat exchange channel with punched V-type delta-winglets

Author(s)
Promthaisong, Pitak
Sripattanapipat, Somchai
Suchatawat, Maturose
Nakhchi, Mahdi Erfanian
Promvonge, Pongjet
Skullong, Sompol
Date Issued
September 1, 2026
Type
Article
DOI
10.1016/j.icheatmasstransfer.2026.111766
Abstract
An experimental examination on the heat transmission improvement of a heat exchange channel (HXC) with punched V-shaped delta-winglets (PVDWs) positioned at regular intervals along the heated wall is presented in the article. This channel has a consistent heat flux for the fluid flow with a Reynolds number (Re) between 5295 and 22,700. By producing vortex flows, the PVDWs help to mix the airflow more rapidly, decrease friction loss via the winglets' louver flap, and direct air jets onto the hot-plate wall. PVDWs with three relative pitches (PR = 1, 1.5, and 2) and five louver flap angles (θ = 90°, 60°, 45°, 30°, and 0°) were spaced regularly on the heated surface. The relative winglet height (BR) was maintained at 0.5 and the attack angle was fixed at 45°. Two types of winglet patterns were in use: inline PVDW and staggered PVDW. Thermal effectiveness factor (TEF), Nusselt number (Nu), and friction factor (f) were all influenced by the PVDW parameters. Varieties of θ and PR are examined parametrically. The smallest Reynolds number results in the greatest rise in frictional factor (fR = 75.07), while the largest Reynolds number gives the greatest improvement in heat transfer rate (NuR = 7.63) for I-PVDW at θ = 0° and PR = 1.0. Both the S-PVDW and the I-PVDW reached their maximum TEFs at θ = 45° and PR = 1, with the former reaching 2.67 and the latter 2.63. Nu and f correlations can also be estimated using their measured data. The best thermal effectiveness and lower friction in the test channel are achieved by using S-PVDWs. The predicted findings were validated by the matching measured data after a 3D numerical study was performed to analyze heat transfer and flow patterns using the realizable k-ε turbulence model. Both the experimental and computational results were in good agreement, and the heat transfer mechanism of the PVDW was elucidated. A reconfiguration of the S-PVDW is performed by reversing the flap angle to increase thermal effectiveness. At θ = −45° and PR = 1, the updated S-PVDW shows a highest TEF of 2.78, which is approximately 4% better than the previous analysis.
Citation
International Communications in Heat and Mass Transfer, 178(P3), 2026
Subjects

Heat exchanger

Heat transfer

Punched winglet

Thermal effectiveness...

Vortex generator

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback