Repository logo
Communities & Collections
Research Outputs
Fundings & Projects
People
Statistics
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. KMITL
  3. Publication
  4. Assessment on hermetic property and mechanical compatibility of various groove-gasket sealing designs for solid oxide fuel cell stack
Loading...
Thumbnail Image

Assessment on hermetic property and mechanical compatibility of various groove-gasket sealing designs for solid oxide fuel cell stack

Author(s)
Punbusayakul, N.
Boonsiri, K.
Charojrochkul, S.
Fungtammasan, B.
Charoensuk, J.
Date Issued
September 1, 2012
Type
Article
DOI
10.1016/j.jpowsour.2012.04.017
Abstract
Assessment among various groove-gasket designs under solid oxide fuel cell operating condition is presented. The gasket is deformable under the stress applied by external loading between 0.13-0.67 MPa. The operating temperature is from 30 to 800 °C. It has an indicated width of 1.95 mm and depth of 2.1 mm., which is accommodated in a square, triangular and U groove channel having the dimension of 2.0 × 2.0 mm 2. From the results, the U shape configuration provides the best performance with immeasurable leak rate under the applying load represented in term of global stress of 0.67 MPa. A stress analysis using Finite Element Method (FEM) tool, ABAQUS™, suggests sufficiently high compressive stress far exceeding the elastic limit with enough coverage of such high-stress area for U-shape design. In contrast, those from square and triangular designs posses relatively lower well-distributed stress and smaller region of highly concentrated stress, respectively. The associated deformed cross section suggests that the gasket has plastically deformed toward the U-shape wall surface at a greater degree than those for triangular-shape design. It can be concluded that the greater region in deformed gasket surface can more effectively reduce interconnectivity of micro channel on the interface between the gasket and the interconnector surfaces. © 2012 Elsevier B.V. All rights reserved.
Citation
Journal of Power Sources, 213, 186-202, 2012
Subjects

Compressive seal

Gas leakage

Groove

SOFC

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback