Repository logo
Communities & Collections
Research Outputs
Fundings & Projects
People
Statistics
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. KMITL
  3. Publication
  4. A development design of ozone generator with a new helix coil electrode for micro bacterial disinfection in hospitals
Loading...
Thumbnail Image

A development design of ozone generator with a new helix coil electrode for micro bacterial disinfection in hospitals

Author(s)
Potivejkul, S.
Leejongpermpoon, S.
Markchun, C.
Kinnares, V.
Date Issued
January 26, 2015
Type
Conference Paper
DOI
10.1109/TENCON.2014.7022375
Abstract
This article presents development of a new helix coil electrode of an ozone generator for disinfection in hospital. In development of the proposed electrode, the optimal spacing between each turn of the helix coil has been investigated. The considered spaces are 1 cm, 2 cm, and 3 cm. To confirm the performance of the proposed electrode, the capability in ozone generation has been considered in an HV laboratory by comparison of ozone concentration generated by the proposed and conventional cylindrical electrodes. The helix coil electrode as an inner electrode was made from copper wire and the cylindrical electrode with radius of 1.5 cm as outer electrode was made of stainless steel. Those two electrodes are separated by air gap with gap spacing of 1 mm and glass material with thickness of 1.4 mm. The inner electrode is connected to a high voltage source and the outer one is connected to ground. In the experiment, air flow rate was set to be 20 l/hr to 150 l/hr. The applied peak high voltage with frequency of 20 kHz used in the experimental is set to be 0 to 6 kV. The experimental result show that the condition of the spacing of 2 cm, air flow rate of 50 l/hr and peak voltage of 6 kV provides the highest ozone concentration of 840 ppm. From the experimental results, it is high possibility that the developed electrode is able to use in ozone generators for micro bacterial disinfection in hospitals.
Citation
IEEE Region 10 Annual International Conference Proceedings TENCON, 2015-January, 2015
Subjects

Electrode

Mycobacterium tubercu...

Ozone

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback