Repository logo
Communities & Collections
Research Outputs
Fundings & Projects
People
Statistics
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. KMITL
  3. Publication
  4. A case study on Thailand's New Teleprotection regulation: Direct transfer trip application in distributed generation network
Loading...
Thumbnail Image

A case study on Thailand's New Teleprotection regulation: Direct transfer trip application in distributed generation network

Author(s)
Chotiwanaporn, Naradon
Chompoo-Inwai, Chow
Date Issued
January 1, 2017
Type
Article
DOI
10.22266/ijies2017.1231.03
Abstract
This research paper presents the new idea of applying the transmission line teleprotection scheme called direct transfer trip (DTT) technique to use with a closed-loop distribution network. A large-scale 163MW gas turbine power plant connected to a three-substation closed-loop distribution network was chosen to be a case study here. A newly-proposed DTT configuration, DTT logic diagram and circuit breaker trip matrix had been redesigned and presented in this paper. For the proposed DTT configuration, several remote terminal units will be installed at every substation connected to the distribution network, whereas the logic controller will be installed at the selected power plant. A huge advantage over the conventionally-installed zoning peer-to-peer protection scheme is that the proposed DTT logic controller is able to almost instantaneously compute and send out the clearing faults command, regardless of fault locations in this particular closed-loop distribution network, while the conventional one cannot in many cases. Additional benefit is that the proposed DTT teleprotection scheme completely prevent the generators from operation in island mode resulting in minimal lost and damages caused from this circumstance. The relay test tool is used to verify the proposed DTT protective capabilities and speed. The simulation and commissioning test results confirm the proper functionality of the proposed technique. The implementation to the real field has been done and presented here as well. What we have learned from this case study shall be a very good guideline for other similar circumstances.
Citation
International Journal of Intelligent Engineering and Systems, 10(6), 20-29, 2017
Subjects

Direct transfer trip

IEC-60834

IEEE-1547

IEEE-C37.236

Island mode

Teleprotection

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback