  4. Dielectric response analysis of mineral oil immersed transformer, Natural Ester(FR3) immersed transformer, and palm oil immersed transformer
Loading...
Thumbnail Image

Dielectric response analysis of mineral oil immersed transformer, Natural Ester(FR3) immersed transformer, and palm oil immersed transformer

Author(s)
Maneerot, Sakda
Nimsanong, Phethai
Siriworachanyadee, Jompatara
Leelajindakrairerk, Monthon
Jariyanurat, Kittipod
Pattanadech, Norasage
Date Issued
June 1, 2019
Type
Conference Paper
DOI
10.1109/ICDL.2019.8796580
Abstract
Currently alternative liquid insulation such as natural ester (FR3) is widely used as distribution transformer insulation because it provides outstandingly dielectric characteristics and natural friendly including highly affordable fire safety. Besides, palm oil is interesting liquid insulation for such transformers because of its distinguish dielectric properties. To analyze the dielectric properties of insulating material, polarization and depolarization current (PDC) measurement is one of the widely accepted non-destructive test technique. This paper presents the dielectric response analysis for the insulation system of a mineral oil immersed transformer, a natural ester (FR3) immersed transformer, and a palm oil immersed transformer by analyzing PDC test results. Three identical single phase transformers with 22kV/460V 30 kVA rated were designed and constructed. The first transformer was fully filled with mineral oil. The second and the third transformer was fully filled with natural ester (FR3) and palm oil respectively. After finishing the construction process, PDC measurement technique was applied for these transformers. The PDC measurement were performed for three case studies as follows: 1) dielectric response for the insulation between high voltage winding and low voltage winding, 2) dielectric response of high voltage winding insulation and low voltage connected to ground 3) dielectric response of high voltage and low voltage winding insulation by which the high voltage lead was connected to the low voltage lead. From the test results, it can be concluded that the dielectric response of the insulation system of the mineral oil immersed transformer was obviously different compared with that of the natural oil (FR3) immersed transformer and the palm oil immersed transformer. Moreover, the PDCs obtained from the tests were also analyzed and reported in this paper.
Citation
Proceedings IEEE International Conference on Dielectric Liquids, 2019-June, 2019
Subjects

Depolarization curren...

Dielectric response a...

Mineral oil

Natural ester

Palm oil

Polarization current

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback