Numerical Investigation of Thermodynamic Performance in Gradient-Pitch Twisted Square Ducts with Variable Aspect Ratio
| dc.contributor.author | Samruaisin, Prachya | |
| dc.contributor.author | Liengsirikul, Sathaporn | |
| dc.contributor.author | Phila, Arnut | |
| dc.contributor.author | Maruyama, Naoki | |
| dc.contributor.author | Shoon Wai, Thiri | |
| dc.contributor.author | Hirota, Masafumi | |
| dc.contributor.author | Naphon, Paisan | |
| dc.contributor.author | Chuwattanakul, Varesa | |
| dc.contributor.author | Chokphoemphun, Suriya | |
| dc.contributor.author | Eiamsa-ard, Smith | |
| dc.date.accessioned | 2026-08-06T10:55:02Z | |
| dc.date.available | 2026-08-06T10:55:02Z | |
| dc.date.issued | 2026-04-01 | |
| dc.description.abstract | This study numerically investigates heat transfer and thermodynamic behavior in twisted square and rectangular air ducts while keeping a constant hydraulic diameter (D<inf>h</inf> = 30 mm). Three aspect ratios are considered (AR = 1.00, 0.75, and 0.50). The heated test section (900 mm) is divided into three equal segments, and three pitch patterns are examined: a uniform pitch (400–400–400 mm, P444) and two axial gradients (300–400–500 mm, P345; 500–400–300 mm, P543). All results are compared to a standard reference, the straight square duct (SD-AR1.00), to ensure fair comparisons across all cases with Reynolds numbers between 5000 and 20,000. Among the twisted ducts, the strongest rectangularity combined with the increasing pitch sequence, TSD-AR0.50-P345, provides the best overall balance. Its heat transfer rises from Nu = 39.39 to 88.62, giving Nu/Nu<inf>0</inf> = 1.493 → 1.433, while the pressure penalty increases to f/f<inf>0</inf> = 1.345 → 1.405. Under cube-root weighting of friction, this case maintains the highest thermal performance factor, TPF = 1.352 at Re = 5000 and TPF = 1.279 at Re = 20,000. Second-law trends support the same ranking: exergy destruction decreases from 12.81 W (baseline) to 8.44 W at Re = 5000 (≈34% reduction) and from 6.54 W to 4.84 W at Re = 20,000 (≈26% reduction). The Bejan number remains high at low Reynolds numbers (≈0.998), indicating heat-transfer irreversibility dominance, but drops at higher Reynolds numbers (≈0.87) as frictional effects become more important. In general, the results show that adding a small axial pitch increase to rectangularity can improve near-wall mixing while reducing losses downstream. This leads to a clear improvement in both first-law performance and exergy-based measures. | |
| dc.identifier.citation | Eng, 7(4), 2026 | |
| dc.identifier.doi | 10.3390/eng7040166 | |
| dc.identifier.issn | 26734117 | |
| dc.identifier.other | 2-s2.0-105037213212 | |
| dc.identifier.uri | https://dspace.kmitl.ac.th/handle/123456789/17982 | |
| dc.source | Eng | |
| dc.subject | aspect ratio | |
| dc.subject | exergy destruction | |
| dc.subject | pitch gradient | |
| dc.subject | rectangular duct | |
| dc.subject | twisted square duct | |
| dc.title | Numerical Investigation of Thermodynamic Performance in Gradient-Pitch Twisted Square Ducts with Variable Aspect Ratio | |
| dc.type | Article |